30 Amp Fusible Indoor Safety Switch
Cutler-Hammer # DG221NGB
2 pole, 3 wire, 2 blades, 2 Class H cartridge fuses (not included), solid neutral, 120/240 Volts AC. Rated 1-1/2 to 3 HP single phase, 3 to 7-1/2 HP 3-phase at 240 Volts only when dual element fuses are used. For residential and commercial applications;suitable for light duty motor circuits and service entrance. For use on systems capable of delivering up to 10,000 RMS, symmetrical fault current. Bolt-on hub provided. No.DS100GK ground kit sold separately. U.L. Listed file No.E5239; meets UL98 for enclosed switches and NEMA standard KS1. Minimize or Learn More more... |
30 Amp Fusible Indoor Safety Switch
Siemens Energy # LF211NU
Single phase, 2 pole, 3 wire, solid neutral, 120/240 Volts. 10,000 AIC with plug fuses (not included). Rated 1-1/2 HP std./3 HP max. Compact size, quick-make, quick-break mechanism. Suitable for use as service entrance equipment. Cover interlock. Bottomcable entry and exit only, no hub provision supplied. Padlocking provision to lock cover closed or to lock in Off position. Lugs suitable for copper or aluminum. Silver plated copper conductors. #14-6 AWG line, #14-8 load lug wire ranges. U.L. Listed fileNo.E4776, NEMA Type GD, meets Federal Specifications WS865C. Minimize or Learn More more... |
30 Amp Fusible Indoor Safety Switch
GE Electric # TG3221CP
2 pole, 3 wire, solid neutral, 240 Volts AC/250 Volts DC. Rated 1-1/2 HP single phase, 3 HP 3-phase NEC standard; and 3 HP single phase, 7-1/2 HP 3-phase time delay at 240 Volts AC. Rated 2 HP at 125 Volts DC, 5 HP at 250 Volts DC. For residential or light commercial applications where duty is not severe. Quick-make, quick-break mechanisms. 100,000 AIC when used with Class R fuses. Suitable for use as service entrance equipment when installed in accordance with National Electrical Code. Hubs sold separately. U.L. Listed, (Enclosed Switches No. 98), and CSA certified. Meets or exceeds NEMA enclosed switch standard KS1-1990 for Type GD. Minimize or Learn More more... |
30 Amp Fusible Indoor Safety Switch
GE Electric # TPF230CP
2 pole, 3 wire, plated copper solid neutral and phase conductor parts, uses plug fuses, 240 Volts AC. Rated 1-1/2 HP NEC Standard and 3 HP time delay at 240 Volts AC, single phase. For residential or light commercial applications where duty is not severe. Typical loads include workshops, pumps, furnaces, water heaters and washers/dryers. Lightweight, corrosion resistant GE Valox with black matte finish. Front slides vertically to turn On and Off. Use only 14-10 AWG copper wire. U.L. Listed (Enclosed Switches No.98); meets or exceeds NEMA standard No.KS1-1990 for Type GD enclosed switches. Minimize or Learn More more... |
30 Amp Fusible Outdoor Safety Switch
GE Electric # TG3221R
2 pole, 3 wire, solid neutral, 240 Volts AC 250 Volts DC. Rated 1-1/2 HP single phase, 3 HP 3-phase NEC standard; and 3 HP single phase, 7-1/2 HP 3-phase time delay at 240 Volts AC. Rated 2 HP at 125 Volts DC, 5 HP at 250 Volts DC. For residential or light commercial applications where duty is not severe. Quick-make, quick-break mechanisms. 100,000 AIC when used with Class R fuses. Suitable for use as service entrance equipment when installed in accordance with National Electrical Code. Removable closingcap. Hubs sold separately. U.L. Listed, (Enclosed Switches No.98), and CSA certified. Meets or exceeds NEMA KS1-1990 Type GD. Minimize or Learn More more... |
30 Amp Fusible Type1
Cutler-Hammer # DP221NGB
2 pole, 3 wire, general duty safety switch, plug fuse type, (Type S, T, OR W) fusible with neutral NEMA 1. 120/240 voltage rating. 1/2 HP at 120V, 1 1/2 HP at 240V, This switch does not have an interlock which prevents being opened when switch is in theON position. Minimize or Learn More more... |
30 Amp Fusible WP Safety Switch
Your One Source # D211NCP
Single phase, 2 pole, 3 wire, 2 blades and fuseholders, factory installed solid neutral, 120/240 Volts AC. Rated 1-1/2 HP. For residential or commercial applications. Typical loads include lighting, air conditioning, appliances and branch circuit disconnects. 100,000 amp short circuit withstand rating with proper plug fuses installed. For No.PK3GTA-1 Field Installable Service Ground Bar Kit. U.L. Listed, meets NEMA standard KS1. Minimize or Learn More more... |
30 Amp Non Fus Indoor Safety Switch
Your One Source # L221N
Single phase, 2 pole, 3 wire, solid neutral, 120/240 Volts AC. Rated 3 HP at 240 Volts AC. Typical loads include workshop or hobby room; and water heater, furnace, garage or well pump disconnect. 10,000 AIC (short circuit rating) with Class H cartridge fuses. Padlock attachment for lock off. U.L. Listed, meets NEMA standard KS1. Minimize or Learn More more... |
30 Amp Non Fusible Indoor Safety Switch
Your One Source # L111N
Single phase, 1 pole, 2 wire, solid neutral, 120/240 Volts AC. Rated 2 HP at 120 Volts AC. Typical loads include workshop or hobby room; and water heater, furnace, garage or well pump disconnect. 10,000 AIC (short circuit rating) with plug fuses. Padlockattachment for lock off. U.L. Listed, meets NEMA standard KS1. Minimize or Learn More more... |
30 Amp Non Fusible Indoor Safety Switch
Your One Source # L211N
Single phase, 2 pole, 3 wire, solid neutral, 120/240 Volts AC, rated 3 HP at 240 Volts AC. Typical include workshop or hobby room; and water heater, furnace, garage or well pump disconnect. 10,000 AIC (short circuit rating) with plug fuses. Padlock attachment for lock off. U.L. Listed, meets NEMA standard KS1. Minimize or Learn More more... |
60 Amp Non Fusible Safety Switch
Siemens Energy # LNF222RU
Single phase, 2 pole, 3 wire, 240 Volts, 10,000 AIC max, rated 10 HP max. Compact size, quick-make, quick-break mechanism. Bottom cable entry and exit only, no hub provision supplied. Padlocking provisions to lock cover or lock in Off position. Lugs suitable for copper or aluminum. Silver plated copper conductors. No.GSGK60 equipment ground kit sold separately. #14-3 AWG line and load wire range. U.L. Listed file No.E4776, NEMA Type GD, meets Federal Specifications WS865C. Minimize or Learn More more... |
Box Outdoor Power Inlet 20 Amp
Reliance # PB20
Allows user to connect a power cord outside where the generator will be running, instead of running a cord through an open door or window. Full-color packaging. UL Listed. 30-amp NEMA configuration. Minimize or Learn More more... |
Box Outdoor Power Inlet 30 Amp
Reliance # PB30
Allows user to connect a power cord outside where the generator will be running, instead of running a cord through an open door or window. Full-color packaging. UL Listed. 30-amp NEMA configuration. Minimize or Learn More more... |
Generator AC Transfer Switch, 50 Amp
Reliance # CQ510C
Suitable for hardwire connection to PB50 power inlet box. Switch has 10 toggle switches to control the circuit breakers in your home under generator power. It is set up at the factory to be connected to a double pole 30 amp breaker(to control a central air conditioner or electric water heater), a double pole 20 amp breaker(to control a well pump) and six 15 amp 120 volt circuit breakers. Integrated, interchangeable one-inch circuit breakers in the switch make multiple connection options possible. 12,500 maximum generator wattage. Analog watt meter. 13" height x 11.75" width x 4.5" depth. UL 100B Listed. Minimize or Learn More more... |
Power Inlet Box, 50 Amp
Reliance # PB50
Outdoor NEMA 3R power inlet box. May be installed outdoors up to 100 feet from a home's load center so your generator can be plugged in outside, away from open doors or windows. Designed to be hard-wired directly to Reliance transfer switches with building wire. Has four combination 1/2" and 3/4" knockouts (one on each side, bottom and back). 6" height x 4" width x 2.63" depth. UL listed. L14-30 NEMA configuration. Minimize or Learn More more... |
Transfer Switch 1 Circuit
Reliance # TF151W
Economical, allows powering an otherwise hard-wired furnace blower motor with a portable generator for heat and to prevent frozen pipes during a power outage. Uses standard 15 amp extension cord. Full-color packaging. UL1008 Listed. Minimize or Learn More more... |
Transfer Switch 6 Circuit
Reliance # 30216A
Built for generators up to 7500 watts. Features 6 large toggle switches that provide easy, safe control of 6 125-Volt circuits, backup pushbutton breakers for each circuit, a steel tie bar that allows a 240-Volt circuit to be hooked up, dual wattage meters that monitor the appliance load on your generator, a built-in L14-30, 30-watt power cord inlet, completely pre-wired conduit that attaches quickly to load center. Full-color packaging. UL1008 Listed. Minimize or Learn More more... |
Waterproof Safety Switch, 30 Amp
Your One Source # D221NRBCP
Single phase, 2 pole, 3 wire, 2 blades and fuseholders, factory installed solid neutral, 120/240 volt AC, with metallic enclosure. Bolt-on hubs. Rated 1-1/2 HP. For residential or commercial applications. Typical loads include lighting, air conditioning,appliances and branch circuit disconnects. 100,000 amp short circuit withstand rating with proper cartridge fuses installed. U.L. Listed, meets NEMA 3R standard. Minimize or Learn More more... |