Case Molded Switch
Your One Source # QO200TRCP
2 pole, 2 wire, 240 Volts AC, rated 10 HP, steel enclosure with molded case. Compact, for use with 75 degree Celsius wire. Advanced design with reliable, quick-make, quick-break operating mechanism. Suitable for use on systems with up to 10,000 RMS symmetrical amps available fault current at 240 Volts AC max when protected by a fuse or circuit breaker rated 60 amps or less. Does not contain overcurrent protection. No.PKHB bracket for stucco, aluminum and vinyl siding sold separately. Ground bar bonded toback. U.L. Listed. Minimize or Learn More more... |
Fused Pull Out AC Disconnect Switch, 30A
Cutler-Hammer # DPF221RP
Air conditioning disconnect, pullout, fused, 2-pole, 120/240 volt AC. Wire size range of #14-3 Cu or Al at 60 or 70 degrees C. Metallic color galvanized steel enclosure, 9" x 5.5" x 3". Enclosure rating; NEMA 3R, rainproof. UL Listed, CSA Approved. Minimize or Learn More more... |
Fusible A C Disconnect Switch
GE Electric # TPF60R
2 pole, 3 wire, 120/240 Volts AC, rated 10 HP. Designed to comply with code requirements for disconnecting means with sight of central air conditioners and heat pumps. Open sides and top for quick installation. Lightweight with plenty of knockouts. Impactand corrosion resistant GE Noryl Resin. Suitable for use as service entrance equipment. Removable closing cap not included. Bonded neutral. 14 - 3 AWG lug wire range. UL 869 Service Equipment, U.L. Listed. Minimize or Learn More more... |
Fusible A C Disconnect Switch
GE Electric # TF60RCP
2 pole, 3 wire, 120/240 Volts AC, rated 10 HP. Uses cartridge fuses. For central air conditioner. Designed to comply with code requirements for disconnecting means within sight of central air conditioners and heat pumps. Removable closing cap not included. Equipment ground. 14-3 AWG lug wire range. UL869 service equipment, U.L. Listed. Minimize or Learn More more... |
Non Fused A C Disconnect 60 Amp
Connecticut Electric # CR610MU
Single phase, 2 pole, 3 wire 240 volts, rated 10 HP. Quality powder coat paint finish. Rugged steel construction. Padlock and/or sealing device to prevent unauthorized entry. For use with aluminum or copper conductors. UL Listed and meets NEC requirements. Convenient kockouts. Minimize or Learn More more... |
Non Fusible A C Disconnect Switch
GE Electric # TFN60RCP
2 pole, 3 wire, 240 Volts AC, rated 10 HP. For central air conditioner. Designed to comply with code requirements for disconnecting means within sight of central air conditioners and heat pumps. Removable closing cap not included. Equipment ground. 14 - 3AWG lug wire range. UL1429 enclosure pullout switch, U.L. Listed. Minimize or Learn More more... |
Non Fusible A C Disconnect Switch
GE Electric # TPN60R
2 pole, 3 wire, 120/240 Volts AC, rated 10 HP. Designed to comply with code requirements for disconnecting means with sight of central air conditioners and heat pumps. Open sides and top for quick installation. Lightweight with plenty of knockouts. Impactand corrosion resistant GE Noryl Resin. Suitable for use as service entrance equipment. Removable closing cap not included. Equipment ground. 14 - 3 AWG lug wire range. UL1429 enclosed pullout switch, U.L. Listed. Minimize or Learn More more... |
Non Fusible A C Disconnect Switch
Cutler-Hammer # AC222URNMP
Single phase, 2 pole, 2 wire, 240 Volts AC. Rated 3 HP at 120 Volts, 10 HP at 240 Volts. For top and bottom entry and exit, with provision for Type H conduit hub. Heavy duty, high strength, rugged polymer enclosure with UV resistant features. Swing-up cover remains in place when in open position, protective shield can be removed for access to fuses. No.GB4 ground bar and No.360-011-24 pullout head replacement sold separately. #14-2 AWG wire range. U.L. Listed file No. E5239. Minimize or Learn More more... |
Non Fusible Disconnect Pull Out Box, 20 Amp
Your One Source # UFP222RGFI
Non-fused 60 amp pullout. 20 amp GFI receptacle mounted to trim for easy wiring. Side-opening door, provides a weatherproof cover for the receptacle per the requirements of NEC 406.8. Mounting slot for pre-hanging during installation. Receptacle factory-wired to ground. Pull-out head storage in OFF position. Convenient knockouts in back, bottom and sides. Does not contain overcurrent protection. Suitable for use on systems with up to 10,000 RMS symmetrical available fault current at 240 volt AC maximum. Wire range Al/Cu: line/load from 14 to 3, equipment grounding terminals (3) from 14 to 4. U.L. Listed. NEMA Type 3R, rated 10 HP, steel enclosure. Minimize or Learn More more... |
Non-Fusible AC Disconnect Switch
Cutler-Hammer # DPU222RP
Single phase, 2 pole, 2 wire, 240 Volts AC,galvanized steel enclosure with molded case switch. Rated 3 HP at 120 Volts, 10 HP at 240 Volts. For bottom entry and exit only. Heavy duty, high strength enclosure with welded and riveted construction. Swing-upcover remains in place when in open position, and includes provision for padlocking. 10,000 AIR. When pullout is in Off position, protective shield can be removed for access to fuses. No.GB4 ground bar and No.96-3258-4 pullout head replacement sold separately. #14-3 AWG wire range. U.L. Listed file No.E5239. Minimize or Learn More more... |
Type 3R AC Disconnect, 60 Amp
Your One Source # FP222RCP
2 pole, 2 wire 240 volt AC, rated 10 HP, steel enclosure. For air conditioner or other single phase applications such as swimming pools and pump houses. Easy access to the line and load terminals. Does not contain overcurrent protection. #14 - #4 AWG wire range. Ground bar bonded to back. U.L. Listed. Minimize or Learn More more... |
60 Amp Non Fusible Safety Switch
Siemens Energy # WN2060U
Single phase, 2 pole, 2 wire, 240 Volt, rated 10 HP. All lugs positioned for bottom entry and exit wiring. Knockouts conveniently located for ease of wiring. Easy mounting for quick installation. Pullout head can be replaced in Off position. 10,000 AIR. 12 - 3 AWG al, 14 - 3 kcmil cu lug wire range. U.L. Listed. Minimize or Learn More more... |
Fusible AC Disconnect Switch, 30 Amp
Cutler-Hammer # ACD221RNMP
Single phase, 2 pole, 2 wire, 240 Volts AC, non-metallic enclosure. Rated 1-1/2 HP at 120 Volts, 3 HP at 240 Volts with time delay fuses (uses Class H cartridge fuses, not included). For top and bottom entry and exit, with provision for Type H conduit hub. Heavy duty, high strength, rugged polymer enclosure with UV resistant features. Swing-up cover remains in place when in open position, and includes provision for padlocking. 10,000 amps RMS symmetrical interrupting rating. Suitable for use as service entrance equipment with ground bar. No.GB4 ground bar and No.360-011-24 pullout head replacement sold separately. #14-2 AWG wire range. U.L. Listed file No. E5239. Minimize or Learn More more... |
Non Fusible A C Disconnect Switch
Your One Source # UFP222R
2 pole, 2 wire, 240 Volts AC, rated 10 HP. Slim, low profile design with ample wiring room. Molded interior trim; no screws to lose. Pullout head can be replaced in Off position or put in pocket for safekeeping. Convenient knockouts in back, bottom and sides. Easy access to the line and load terminals. Does not contain overcurrent protection. Suitable for use on systems with up to 10,000 RMS symmetrical available fault current at 240 Volts AC max when protected by fuse or circuit breaker rated 60 amps orless. Ground bar bonded to back. 14 - 10, 8, 6 - #4, #3 AWG wire range. U.L. Listed. Minimize or Learn More more... |
Outdoor AC Disconnect Box, 30 Amp
Your One Source # FP221R
2 wire 240 volt AC steel enclosure. For air conditioner or other single phase applications such as swimming pools and pump houses. Easy access to the line and load terminals. Does not contain overcurrent protection. #14 - #4 AWG wire range. U.L. Listed. Minimize or Learn More more... |