Main Load Center, 70 Amp
Cutler-Hammer # CH2L70RP
Rainproof galvanized steel enclosure. Single phase, 3 wire, insulated/bondable neutral, 2 (3/4") spaces, 4 poles with CHNT breakers, 120/240 volt AC. With closure plates, hubs and ground bar No.GBKS or No.GBK520 sold separately. Copper bus bar. In service entrance application, where neutral is bonded, unused neutral connections may be used for termination of equipment grounds. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not used as a lighting and appliance panelboard. #14 - 2 main lug wire range. Electrostatic powder coat, baked urethane painted sandalwood. Rotate 180 degrees for bottom feed. U.L. Listed file E8741. Minimize or Learn More more... |
Main Lug Load Center, 100 Amp
Your One Source # HOM612L100RBCP
Rainproof gavanelle enclosure. Single phase, 3 wire, solid neutral, 6 spaces, 12 circuits, 6 tandem breakers accepted, 120/240 Volts AC. 10,000 AIR. Factory installed main lugs. Furnished with removable closing cap covering 2", bushed opening. B-hubs andNo.PK7GTA ground bar sold separately. Straight in main design. #8 - 1 AWG main wire. Rotate 180 degrees for bottom feed. U.L. Listed. Minimize or Learn More more... |
Main Lug Load Center, 100 Amps
Your One Source # QO612L100RBCP
Rainproof gavanelle enclosure. Single phase, 3 wire, solid neutral, 6 spaces, 12 circuits, 6 tandem breakers accepted, 120/240 Volts AC. 10,000 AIR. Factory installed fixed main lugs. Furnished with removable B-cap covering 2.5" extruded opening. B-hubs and No. PK7GTA ground bar sold separately. Slot/square drive screws. Straight in main design. #8 - 1 AWG main wire. Rotate 180 degrees for bottom feed. U.L. Listed. Minimize or Learn More more... |
Main Lug Load Center, 125 Amp
Cutler-Hammer # BR48L125SP
Steel enclosure. Single phase, 3 wire, insulated/bondable neutral, 4 (1") spaces, 8 poles, 120/240 V. No. GBK10 ground bars and doors sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service application. #14 - 1/0 AWG wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. U.L. Listed file E8741. Minimize or Learn More more... |
Main Lug Load Center, 125 Amp
Your One Source # QO120L125GC
Welded sheet steel enclosure. Single phase, 3 wire, split neutral, 20 spaces, 20 circuits, indoor main lugs,120/240 volt. Combination flush/surface door and ground bar kit included. Shielded copper bus bar, slot/square drive screws. U.L. Listed. Minimize or Learn More more... |
Main Lug Load Center, 125 Amps
Cutler-Hammer # BR612L125FDP
Steel enclosure. Single phase, 3 wire, insulated/bondable neutral, 6 (1") spaces, 12 poles, 120/240 V. Furnished with door; No. GBK10 ground bar sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #14 - #1 AWG wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. U.L. Listed file E8741. Minimize or Learn More more... |
Main Lug Load Center, 200 Amp
Cutler-Hammer # BR1224L200R
Rainproof galvanized steel enclosure. Single phase, 3 wire, insulated/bondable split neutral, 12 (1") spaces 24 poles, 120/240 volt AC. Has notch for No.BRHDK125 hold down kit. With closure plates, hubs and ground bar kits (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 6 main disconnecting means are provided and when not used as lighting and appliance panelboard. Twin neutral with non-removable cross bus. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #1 - 300 kcmil wire. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. U.L. Listed file E52977. Minimize or Learn More more... |
Main Lug Load Center, 70 Amp
Your One Source # QO24L70RBCP
|
Main Lug Panel, 30 Amp
Your One Source # QO2L30SCP
Steel enclosure. Single phase, 3 wire, solid neutral, 2 spaces, 2 circuits, 120/240 V. 10,000 AIR. No. PK3GTA-1 ground bars sold separately. Will not accept Qwik-Gard QO-GFI circuit breakers. Slot/square drive screws, 3 ground bar mounting locations. Straight in main design. Tangential main service knockouts. Mains rated 25 amp when aluminum wire is used. #12 - 10 A1 or #14 - 10 Cu AWG main wire. Rotate 180 degrees for bottom feed. U.L. Listed. Minimize or Learn More more... |
Main Panel Circuit Breaker, 200 Amp
Siemens Energy # LC4040B1200
Single phase - 3 wire; 120/240 volt; 40 circuits maximum; 40 - 1" spaces; 10,000 AIC with combination cover. 200 amp main breaker included. UL listed. Minimize or Learn More more... |
Mainbreaker Loadcenter, 200 Amp
Siemens Energy # LC3040B1200P
200 amp main breaker loadcenter. Single phase, 3 wire, split neutral, 30 spaces and 40 circuits. 120/240 volt. Indoor with combination surface/flush cover. Includes 6 single pole and two double breakers. 22,000 AIC rating. Aluminum bus bar. One-piece steel interior allows for easy removal. Keyhole and nail slots provide easy enclosure mounting. Knockout patterns sized for maximum wiring flexibility. U.L. listed. Minimize or Learn More more... |
Mainbreaker Loadcenter, 200 Amp
Siemens Energy # LC2040B1200
200 amp main breaker loadcenter. Single phase, 3 wire, split neutral, 20 spaces and 40 circuits. 120/240 volt. Indoor with combination surface/flush cover. 22,000 AIC rating. Aluminum bus bar. One-piece steel interior allows for easy removal. Keyhole andnail slots provide easy enclosure mounting. Knockout patterns sized for maximum wiring flexibility. U.L. listed. Minimize or Learn More more... |
Outdoor Main Panel Circuit Breaker, 125 Amp
Siemens Energy # LW004NRU
Convertible To Main Breaker Using Double Pole Breaker 2 Full Spaces. 4 Space, 8 Circuit, Combination Mount. Minimize or Learn More more... |
Outdoor Main Panel Circuit Breaker, 125 Amp
Siemens Energy # LC004NSU
Single phase - 3 wire; 120/240 volt; 8 circuits maximum with 4 - 1" spaces; 10,000 AIC. UL listed. Minimize or Learn More more... |
Rainproof Load Center, 100 Amp
Your One Source # QO816L100RBCP
Rainproof gavanelle enclosure. Single phase, 3 wire, solid neutral, 8 spaces, 16 circuits, 8 tandem breakers accepted, 120/240 volt AC. 10,000 AIR. Factory installed fixed main lugs. Furnished with removable B-cap covering 2.5" extruded opening. B-hubs and No. PK7GTA ground bar sold separately. Slot/square drive screws. Straight in main design. #8 - 1 AWG main wire. Rotate 180 degrees for bottom feed. UL Listed. Minimize or Learn More more... |
Six Circuit Main Lug Load Center, 125 Amp
GE Electric # TLM612RCU
(12) 1 pole 1/2" spaces. 65,000 AIC. Single-phase, Three-wire, 120/240 volt AC. Convertible. Full-length neutrals are easier to wire, reducing installation time and cost. Removable closing cap. Minimum 100 percent neutral terminations. Sturdy copper bus and galvanized box increase durability and reliability. Combination slotted/Robertson screws speed wiring. All holes are rated for 14-4 wire. 100 per cent rated split neutral on each side. Load centers accept Q Line circuit breakers, including GE's exclusive 1/2" THQPs. UL listed. Minimize or Learn More more... |
Twenty Four Circuit Main Breaker, 100 Amp
Siemens Energy # LC1224B1100
Single phase - 3 wire; 120/240 volt; 24 circuits maximum; 12 - 1" spaces; Combination cover; 10,000 AIC. 100 amp main breaker included. UL listed. Minimize or Learn More more... |
Contractor Load Center Kit, 200 Amp
GE Electric # TM2020CCUPL5
Includes 1 No. TM2020CCU. 200 amp, 40 spaces maximum indoor load center, 6 THQL single pole 20 amp, 1 THQL double pole 30 amp and 1 THQL double pole 50 amp. Minimize or Learn More more... |
GE Load Center, 200 Amp
GE Electric # TM4020CCU
(40) 1" spaces; 22,000 AIC. Single-phase, three-wire, 120/240 volt AC. One-piece interior removes and reinstalls easily. Full-length neutrals are easier to wire, reducing installation time and cost. Minimum 100% neutral terminations. Sturdy copper bus and galvanized box increase durability and reliability. Combination slotted/Robertson screws speed wiring. All holes are rated for 14-4 wire. 100 per cent rated split neutral on each side. Load centers accept Q Line circuit breakers, including GE's exclusive 1/2"THQPs. 100-225 amp devices have removable closing cap. Minimize or Learn More more... |
Main Lug Load Center, 60 Amp
Cutler-Hammer # BR24L70FP
Single phase, 3 wire, insulated/bondable neutral, 2 (1") spaces, 4 poles, 120/240 volt AC. No. GBK5 or No. GBK520 ground bars and doors sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not used as a lighting and appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #8 - #2 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. U.L. Listed file E8741. Minimize or Learn More more... |
Residential Main Breaker Load Center, 200 Amp
Cutler-Hammer # BR2040B200
Steel enclosure. Single phase, 3 wire, insulated/bondable split neutral, 20 (1") spaces, 40 poles, 120/240 V. Main breaker type BW at 10,000 AIR. Ground bar kit (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. Twin neutral with non-removable cross bus connecting them. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #2 - 300 kcmil wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed; orientation of main breaker handle consistent with NEC 240-81 requirements because it operates horizontally. U.L. Listed file E52977. Minimize or Learn More more... |