200 Amp Circuit Breaker Enclosure
Cutler-Hammer # RCC200SEBP
Single phase, 3 wire. 2 pole, 120/240 Volts AC. 10,000 AIC. Includes No. ECB225R enclosure with factory installed No. BW2200 circuit breaker and ground lug. No. GBK5P ground bar and DS type hub sold separately (Aubuchon Iem # 635165). For use as main breaker or service disconnect, as service entrance equipment when used with ground bar. Electrostatic powder coat, baked urethane painted. #2 - 300 kcmil wire range. U.L. Listed. Minimize or Learn More more... |
Circuit Breaker Load Center, 100 Amp
Your One Source # HOM20M100C
Welded sheet steel. Single phase, 3 wire, split neutral, 20 spaces, 20 circuits, 120/240 V. 10,000 AIR factory installed main breaker, QOM1 main frame size. 3 different mounting locations for ground bar, use bar No.PK15GTA sold separately. Rugged bus bar, slot/square drive screws. Straight in main design. Tangential main service knockouts. Rotate entire device 180 degrees for bottom feed. #4 - 2/0 AWG main wire. Gray baked-on enamel finish. U.L. Listed. Minimize or Learn More more... |
Circuit Breaker Main Panel, 125 Amp
Siemens Energy # LC008DSU
Single phase type 1 with 8-1" spaces, 16 circuits. Use neutral lug kit DLK1 or DLK2 as required. Indoor closure with door. Minimize or Learn More more... |
Circuit Breaker Main Panel, 200 Amp
Siemens Energy # LC3040B1200
Single phase; 30-1" spaces; 40 circuits. |
Combination Service Entrance Device
Your One Source # SC2040M200C
Rainproof all-in-one combination service entrance device. Single phase, 3 wire. 10,000 short circuit rating. 20 space, 40 circuit. Meets EUSERC standards. Service disconnects are supplied factory installed. Supplied with 100% branch neutrals. Meets Federal Specification W-P-115c as Type 1, Class 2. Convertible to semiflush with SC200F flange kit (sold separately). UL listed, suitable only for use as service equipment. Minimize or Learn More more... |
Enclosed Circuit Breaker Box, 200 Amp
Your One Source # QOM2E22OONRB
Gavanelle enclosure. Single phase, 3 wire, 2 pole, groundable neutral assembly, 120/240 volt. Requires 200 amp maximum/2 pole No. Q2L2200 breaker. Factory installed ground and neutral lugs. Includes equipment ground kit, hub sold separately. Will take QOor QO GFCI circuit breakers. For use as main breaker or service disconnect, as service entrance equipment when used with ground bar. #4 - 300 kcmil wire size. U.L. Listed. Minimize or Learn More more... |
Four Circuit Outdoor Main Panel Breaker Box, 60 Amp
Siemens Energy # LW002GRU
Single phase - 3 wire; 120/240 volt; 4 circuits maximum; 2 - 1" spaces ; 10,000 AIC. UL listed. Minimize or Learn More more... |
Homeline Load Center, 200 Amp
Your One Source # HOM40M200C
Welded sheet steel enclosure. Single phase, 3 wire, split neutral, 40 spaces, 40 circuits, 120/240 V. 10,000 AIR factory installed main breaker, QOM2 main frame size. 3 different mounting locations for ground bar, use No.PK23GTA bar sold separately. Rugged bus bar, slot/square drive screws. Straight in main design. Tangential main service knockouts. Rotate entire device 180 degrees for bottom feed. #4 - 250 kcmil main wire. Gray baked-on enamel finish. U.L. Listed. Minimize or Learn More more... |
Homeline Load Center, 70 Amp
Your One Source # HOM24L70SCP
Steel enclosure. Single phase, 3 wire, solid neutral, 2 spaces, 4 circuits, 2 tandem breakers accepted, 120/240 V. 10,000 AIR. No. PK3GTA-1 ground bar sold separately. Slot/square drive screws, 3 ground bar mounting locations. Straight in main design. Tangential main service knockouts. Use #10 maximum wire size for GFI circuit breaker. #12 - 3 A1 or #14 - 40 Cu AWG main wire. Rotate 180 degrees for bottom feed. U.L. Listed. Minimize or Learn More more... |
Homeline Residential Load Center, 100 Amps
Your One Source # HOM1224M100TC
Welded sheet steel. Single phase, 3 wire, split neutral, 12 spaces, 24 circuits, 12 tandem breakers accepted, 120/240 V. 10,000 AIR factory installed main breaker. QOM1 main frame size. 3 different mounting locations for installed ground bar. Rugged bus bar, slot/square drive screws. Straight in main design. Tangential main service knockouts. Rotate entire device 180 degrees for bottom feed. #4 - 2/0 Awg main wire. Gray baked on-enamel finish. U.L. Listed. Minimize or Learn More more... |
Indoor Main Lug Load Center, 125 Amp
Cutler-Hammer # BR1624L125
Single phase, 3 wire, insulated/bondable split neutral, 16 (1") spaces, 24 poles, 120/240 volt. Has notch for No.BREQS125 hold down kit. Ground bar kits (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. Twin neutral with non-removable cross bus connecting them. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #6 - 2/0 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. U.L. Listed file E52977. Minimize or Learn More more... |
Indoor QO Load Center, 100 Amp
Your One Source # QO112M100C
Welded sheet steel. Single phase, 3 wire, split neutral, 12 spaces, 12 circuit, 120/240 V. 22,000 AIR factory installed main breaker U.L. Listed for use ahead of QO and QOT 10,000 AIR branch breakers to permit their application systems with up to 22,000 amps available fault current. QOM1 frame size. 3 mounting locations for ground bar, use bar No.PK9GTA sold separately. Shielded copper bus bar, slot/square drive screws. Straight in main design. Tangential main service knockouts. Rotate entire device 180 degrees for bottom feed. #4 - 1 AWG main wire. Gray baked-on enamel finish. U.L. Listed. Minimize or Learn More more... |
Load Center Value Pack, 100 Amp
Cutler-Hammer # BR2020B100V
Galvanized steel enclosure. Single phase, 3 wire, insulated/bondable split neutral, 20 (1") spaces, 20 poles, 120/240 volt. Main breaker type BR at 10,000 AIR. Ground bar kit (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. Twinneutral with non-removable cross bus connecting them. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #4 - 1/0 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed; orientation of main breaker handle consistent with NEC 240-81 requirements because it operates horizontally. U.L. Listed file E52977. Minimize or Learn More more... |
Load Center Value Pack, 200 Amp
Cutler-Hammer # BR4040B200V2
Galvanized steel enclosure. Single phase, 3 wire, insulated/bondable split neutral, 40 (1") spaces, 40 poles, 120/240 volt. Main breaker type BW at 10,000 AIR. Ground bar kit (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. Twin neutral with non-removable cross bus connecting them. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #2 - 300 kcmil wire range. Electrostatic powder coat, baked urethane painted. Rotate180 degrees for bottom feed; orientation of main breaker handle consistent with NEC 240-81 requirements because it operates horizontally. U.L. Listed file E52977. Minimize or Learn More more... |
Load Center Value Pack, 200 Amp
Cutler-Hammer # BR3040B200V2
Galvanized steel enclosure. Single phase, 3 wire, insulated/bondable split neutral, 30 (1") spaces, 40 poles, 120/240 volt. Main breaker type BW at 10,000 AIR. Ground bar kit (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. Twin neutral with non-removable cross bus connecting them. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #2 - 300 kcmil wire range. Electrostatic powder coat, baked urethane painted. Rotate180 degrees for bottom feed; orientation of main breaker handle consistent with NEC 240-81 requirements because it operates horizontally. U.L. Listed file E52977. Minimize or Learn More more... |
Main Breaker Load Center, 100 Amp
Cutler-Hammer # BR1620B100P
Galvanized steel enclosure. Single phase, 3 wire, insulated/bondable split neutral, 16 (1") spaces, 20 poles, 120/240 volt. Main breaker type BR at 10,000 AIR. Ground bar kit (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. Twinneutral with non-removable cross bus connecting them. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #4 - 1/0 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed; orientation of main breaker handle consistent with NEC 240-81 requirements because it operates horizontally. U.L. Listed file E52977. Minimize or Learn More more... |
Main Breaker Load Center, 100 Amp
Cutler-Hammer # BR1020B100RF
Rainproof galvanized steel enclosure. Single phase, 3 wire, insulated/bondable split neutral, 10 (1") spaces, 20 poles, 120/240 volt AC. Main breaker type BR at 10,000 AIC. Includes feed-thru lugs for both phase and neutral conductors. With hub closure plates, hubs and ground bar kit (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. Twin neutral with non-removable cross bus connecting them. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #4 - 1/0 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed; orientation of main breaker handle consistent with NEC 240-81 requirements because it operates horizontally. U.L. Listed file E52977. Minimize or Learn More more... |
Main Breaker Load Center, 200 Amp
Cutler-Hammer # BR2040B200R
Rainproof galvanized steel enclosure. Single phase, 3 wire, insulated/bondable split neutral, 20 (1") spaces, 40 poles, 120/240 volt AC. Main breaker type BW at 10,000 AIC. Furnished with hub closure plates, hubs and ground bar kit (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. Twin neutral with non-removable cross bus connecting them. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #2 - 300 kcmil wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed; orientation of main breaker handle consistent with NEC 240-81 requirements because it operates horizontally. U.L. Listed file E52977. Minimize or Learn More more... |
Main Breaker Residential Load Center, 100 Amp
Cutler-Hammer # BR1220B100
Galvanized steel enclosure. Single phase, 3 wire, insulated/bondable split neutral, 12 (1") spaces, 20 poles, 120/240 V. Main breaker type BR at 10,000 AIR. Ground bar kit (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. Twin neutral with non-removable cross bus connecting them. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #4 - 1/0 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed; orientation of main breaker handle consistent with NEC 240-81 requirements because it operates horizontally. U.L. Listed file E52977. Minimize or Learn More more... |
Main Disconnect Breaker Box, 100 Amp
Your One Source # QO120M100C
Welded sheet steel. Single phase, 3 wire, split neutral, 20 spaces, 20 circuits, 120/240 V. 22,000 AIR factory installed main breaker U.L. Listed for use ahead of QO and QOT 10,000 AIR branch breakers to permit their application systems with up to 22,000amps available fault current. QOM1 frame size. 3 mounting locations for ground bar, use bar No.PK15GTA sold separately. Shielded copper bus bar, slot/square drive screws. Straight in main design. Tangential main service knockouts. Rotate entire device 180 degrees for bottom feed. #4 - 1 AWG main wire. Gray baked-on enamel finish. U.L. Listed. Minimize or Learn More more... |
Main Disconnect Breaker Box, 200 Amp
Your One Source # QO140M200C
Welded sheet steel enclosure. Single phase, 3 wire, split neutral, 40 spaces, 40 circuits, 120/240 V. 22,000 AIR factory installed main breaker U.L. Listed for use ahead of QO and QOT 10,000 AIR branch breakers. QOM2 frame size. 3 mounting locations for ground bar, use bar No.PK23GTA sold separately. Shielded copper bus bar, slot/square drive screws. Straight in main design. Tangential main service knockouts. Rotate entire device 180 degrees for bottom feed. #4 - 250 kcmil main wire. Gray baked-on enamelfinish. U.L. Listed. Minimize or Learn More more... |