Fuse Plug Panel, 30 Amp
Siemens Energy # GP321NU
Thirty amp fuse plug panel |
Main Lug Load Center, 60 Amps
Siemens Energy # LCOO2GSU
Indoor enclosure, surface mount without door. Single phase, 3 wire, 120/240 Volts. Includes main lugs. Minimize or Learn More more... |
150 Amp Main Break Load Center
Siemens Energy # G3030B1150
Single phase, 3 wire, split neutral, 30 spaces and 30 circuits max 1-pole, 14 max 2-pole, 120/240 Volts ac. Factory installed 22,000 AIR main breaker. May be installed on higher rated systems when protected by a circuit breaker feeder with a higher AIR rating. Accomodates only fully size breakers. One piece plated aluminum bus bar. 100% circuit breaker twistouts. Positive load side circuit breaker hook rail. When used as service equipment, any unused neutral position may be used for equipment grounding.Rotate entire device 180 degrees for bottom feed. Gray enamel finish. U.L. Listed suitable for use as service equipment, complies fully with NEC and UL requirements for Class CTL. Ten Year Limited Warranty. Minimize or Learn More more... |
40 Amp Surface Mount Load Center
GE Electric # TL240RCU
Single phase, 3 wire, 4 total 1-pole spaces, 120/240 Volts ac. 2 spaces 1p, 1 space 2p max 1"THQL; 4 spaces 1p, 1 space 2p max 1/2"THQP. 22,000 AIC. Smaller and lighter box yet maintains optimum wire bending space. Includes tin-plated copper bus, galvanized mounting rails, combo slotted/#2 Robertson screws, 100% neutral terminations and full length bondable neutral. Furnished with removable closing cap, hubs and No.TGK4 equipment ground kit sold separately. Suitable for use as service equipment when installed in accordance with the NEC. 14-4 AWG main lug wire range. Bottom feed entrance is available by running wire on the side. U.L. Listed, No.67 Panelboards. Minimize or Learn More more... |
60 Amp Main Lug Load Center
Siemens Energy # W0204ML1060U
Single phase, 3 wire, solid neutral, 2 spaces and 4 circuits max 1-pole, 1 QP breaker max 2-pole, 120/240 Volts ac. 10,000 AIR. With closure plates, HS style hubs sold separately. One piece plated aluminum bus bar. 100% circuit breaker twistouts. Will not accomodate 2-pole GFCI or circuit breaker with shunt trip. Positive load side circuit breaker hook rail. When used as service equipment, any unused neutral position may be used for equipment grounding. Rotate entire device 180 degrees for bottom feed. Gray enamel finish. CSA and U.L Listed, complies fully with NEC and UL requirements for Class CTL. Ten Year Limited Warranty. Minimize or Learn More more... |
60 Amps Main Lug Load Center
Siemens Energy # E0204ML1060SU
Single phase, 3 wire, solid neutral, 2 spaces and 4 circuits max 1-pole, 1 QP breaker max 2-pole, 120/240 Volts AC. 10,000 AIR. One piece plated aluminum bus bar, heavier main bus for cooler operation, direct cable connection to bus bar. Main lugs and neutral on same plane, same drive tool. 100% circuit breaker twistouts. Positive load side circuit breaker hook rail. When used as service equipment, any unused neutral position may be used for equipment grounding. Simple upper pan adjustment after trim isinstalled for flush leveling. Rotate entire device 180 degrees for bottom feed. Gray enamel finish. CSA and U.L. Listed, complies fully with NEC and U.L. requirements for Class CTL. Ten Year Limited Warranty. Minimize or Learn More more... |
70 Amp Main Lug Load Center
Your One Source # HOM24L70FCP
Single phase, 3 wire, solid neutral, 2 spaces, 4 circuits, 2 tandem breakers accepted, 120/240 Volts AC. 10,000 AIR. No. PK3GTA-1 ground bar sold separately. Slot/square drive screws, 3 ground bar mounting locations. Straight in main design. Tangential main service knockouts. Use #10 maximum wire size for GFI circuit breaker. #12 - 3 A1 or #14 - 4 Cu AWG main wire. Rotate 180 degrees for bottom feed. U.L. Listed. Minimize or Learn More more... |
70 Amp Main Lug Load Center
Your One Source # HOM24L70RBCP
Single phase, 3 wire, solid neutral. 2 spaces, 4 circuits, 2 tandem breakers accepted, 120/240 Volts ac. 10,000 AIR. Factory installed fixed main lugs. furnished with removable B-cap covering 2" bushed opening, B-hubs and No.PK4GTA ground bar sold separately. Use #10 max wire for GFI circuit breaker. straight in main design. #12 - 3 Al or #14 - 4 Cu AWG main wire. Rotate 180 degrees for bottom feed. U.L. Listed. Minimize or Learn More more... |
70 Amp Main Lug Load Center
Cutler-Hammer # BR24L70RP
Single phase, 3 wire, insulated/bondable movable neutral, 2 (1") spaces, 4 poles, 120/240 Volts ac. With closure plates, hubs and No.GBK5 or GBK520 ground bar kits (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not used as a lighting and appliance panelboard. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #8 - #2 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. U.L. Listed file E8741. Minimize or Learn More more... |
70 Amp Surface Mount Load Center
Your One Source # QO24L70SCP
Single phase, 3 wire, solid neutral, 2 spaces, 4 circuits, 2 tandem breakers accepted, 120/240 Volts AC. 10,000 AIR. No. PK4GTA ground bar sold separately. Slot/square drive screws, 3 ground bar mounting locations. Straight in main design. Tangential main service knockouts. Use #10 maximum wire size for GFI circuit breaker. #12 - 3 A1 or #14 - 4 Cu AWG main wire. Rotate 180 degrees for bottom feed. U.L. Listed. Minimize or Learn More more... |
70 Amp Surface Mount Load Center
GE Electric # TL270RCU
Single phase, 3 wire, 4 total 1-pole spaces, 120/240 Volts ac. 2 spaces 1p, 1 space 2p max 1"THQL; 4 spaces 1p, 1 space 2p max 1/2"THQP. 22,000 AIC. Includes tin-plated copper bus, galvanized mounting rails, combo slotted/#2 Robertson screw. 100% neutralterminations and full length bondable neutral. Furnished with removable closing cap, hubs and No.TGK4 equipment ground kit sold separately. Suitable for use as service equipment when installed in accordance with the NEC. 6 - 3 AWG main lug wire range. Bottom feed entrance is available by running wire on the side. U.L. Listed, No.67 Panelboards. Minimize or Learn More more... |
Improvement Value Pack
Your One Source # HOMVP9
Includes one No. HOM3040M200TC 200 amp, 30 space/40 circuit max. indoor load center with equipment ground bar kit, six No. HOM115 15 amp single pole circuit breakers, six No. HOM120 20 amp single pole circuit breakers, one No. HOM230 30 amp double pole circuit breaker and one No. HOM250 50 amp double pole circuit breaker. Minimize or Learn More more... |
Indoor Flush with Door Load Center
GE Electric # TLM812FCUD
Single phase, 3 wire, 16 total 1-pole spaces, 120/240 Volts AC. 8 spaces 1p, 4 spaces 2p max 1" THQL; 16 spaces 1p , 6 spaces 2p max 1/2" THQP. 22,000 AIC, with door. Includes tin-plated copper bus, galvanized mounting rails, combo slotted/#2 Robertson screws, 100% neutral terminations and full length bondable neutral. No.TGK12 equipment ground kit sold separately. Suitable for use as service equipment when installed in accordance with the NEC. 6 - 3 AWG main lug wire range. U.L. Listed for bottom mounted lugs by installing complete unit upside down, No.TRL22B bottom feed door handle not included. U.L. Listed, No.67 panelboards. For converting to main breaker use No.THQLRK2 retainer kit and 2-pole circuit breaker (not included). Minimize or Learn More more... |
Indoor Flush with Door Load Center
GE Electric # TLM612FCUD
Single phase, 3 wire, 12 total 1-pole spaces, 120/240 Volts AC. 6 spaces 1p, 3 spaces 2p max 1" THQL; 12 spaces 1p , 4 spaces 2p max 1/2" THQP. 22,000 AIC, with door. Includes tin-plated copper bus, galvanized mounting rails, combo slotted/#2 Robertson screws, 100% neutral terminations and full length bondable neutral. No.TGK12 equipment ground kit sold separatelty. Suitable for use as service equipment when installed in accordance with the NEC. 6 - 3 AWG main lug wire range. U.L. Listed for bottom mounted lugs by installing complete unit upside down, No.TRL22B bottom feed door handle not included. U.L. Listed, No.67 panelboards. For converting to main breaker use No.THQLRK2 retainer kit and 2-pole circuit breaker (not included). Minimize or Learn More more... |
Indoor Surface with Door Load Center
GE Electric # TLM812SCUD
Single phase, 3 wire, 16 total 1-pole spaces, 120/240 Volts AC. 8 spaces 1p, 4 spaces 2p max 1" THQL; 16 spaces 1p , 6 spaces 2p max 1/2" THQP. 22,000 AIC, with door. Includes tin-plated copper bus, galvanized mounting rails, combo slotted/#2 Robertson screws, 100% neutral terminations and full length bondable neutral. No.TGK12 equipment ground kit sold separately. Suitable for use as service equipment when installed in accordance with the NEC. 6 - 3 AWG main lug wire range. U.L. Listed for bottom mounted lugs by installing complete unit upside down, No.TRL22B bottom feed door handle not included. U.L. Listed, No.67 panelboards. For converting to main breaker use No.THQLRK2 retainer kit and 2-pole circuit breaker (not included). Minimize or Learn More more... |
Main Lug Load Center, 70 Amp
Cutler-Hammer # BR24L70SP
Steel enclosure. Single phase, 3 wire, insulated/bondable movable neutral, 2 (1") spaces, 4 poles, 120/240 volt. No.GBK5 or GBK520 ground bars and doors sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equi Minimize or Learn More more... |