200 Amp GE Load Center
GE Electric # TM3220CCU
Single phase, 3 wire, 40 total 1-pole spaces, 120/240 Volts ac. 32 spaces 1p, 16 spaces 2p max 1" THQL; 16 spaces 1p, 6 spaces 2p max 1/2" THQP. 22,000 AIC. Includes tin-plated copper bus, galvanized mounting rails, steel studs connect bus bar to main breaker, combo slotted/#2 Robertson screws, 100% neutral terminations, full length split neutral bondable on either side, remove tie bat to split neutral/ground. No. TGK32 equipment ground kit sold separately. Suitable for use as service equipment when installed in acordance with the NEC. 1 - 250 (Cu) or 2/0 - 250 (A1) AWG main lug wire range. U.L. Listed, No. 67 Panelboard. Minimize or Learn More more... |
200 Amp GE Load Center
GE Electric # TM2020CCU
Single phase, 3 wire, 40 total 1-pole spaces, 120/240 Volts ac. 20 spaces 1p, 10 spaces 2p max 1" THQL; 40 spaces 1p, 20 spaces 2p max 1/2" THQP. 22,000 AIC. Includes tin-plated copper bus, galvanized mounting rails, steel studs connect bus bar to main breaker, combo slotted/#2 Robertson screws, 100% neutral terminations, full length split neutral bondable on either side, remove tie bar to split neutral/ground. No. TGK24 or TGK42 equipment ground kit sold separately. Suitable for use as service equipmentwhen installed in accordance with NEC. 1 - 250 (Cu) or 2/0 - 250 (A1) AWG main lug wire range. U.L. Listed, No. 67 Panelboards. Minimize or Learn More more... |
200 Amp Indoor Nema1 Loadcenter
Your One Source # QO12040M200C
Single phase, 3 wire, split neutral, 20 spaces, 40 circuits, 20 tandem breakers accepted, 120/240 Volts ac. 22,000 AIR factory installed main breaker U.L. Listed for use ahead of QO and QOT 10,000 AIR branch breakers to permit their application systems with up to 22,000 amps available fault current. QOM2 frame size. 3 mounting locations for ground bar, use bar No. PK23GTA sold separately. Shielded copper bus bar, slot/square drive screws. Straight in main design. tangential main service knockouts. Rotateentire device 180 degrees for bottom feed. #4 - 250 kcmil main wire. Gray baked-on enamel finish. U.L. Listed. Minimize or Learn More more... |
200 Amp Load Center F T Lugs
Your One Source # HOM816M200FTRB
Single Phase, 3 Wire, insulated/bonded split neutral, 8 spaces, 16 circuits max, 8 tandem breakers accepted. 120/240 Volts ac. 10,000 AIR. With B-cap covering 2 bushed opening, hubs and No.PK15GTA-L ground bar sold separately. For use as service entrancepanel. Ideal for mobile homes and farm applications. Straight in main design convertible for flexibility. #4 - 250 kcmil main wire; rated 200 amp when using copper wire, reference NEC 310-16 Note 3 when using aluminum. U.L. Listed. Minimize or Learn More more... |
200 Amp Load Center F T Main Breaker
Siemens Energy # W0404MB1200CT
Single phase, 4 spaces, 8 circuits, 120/240 Volts. 10,000 AIR. Factory installed main breaker. Additional spaces allow connection of external circuits such as yard lights. One 2" No. HS200 hub included. Normally used as a means of disconnecting power toa mobile home panel, but also used as a disconnect for houses. Aluminum bus bar insulates and secures interior. Drop hinge door. Gray enamel finish. Pole mountable. U.L. Listed for use as service entrance equipment. Ten Year Limited Warranty. Minimize or Learn More more... |
200 Amp Main Break Load Center
Siemens Energy # G2040B1200
Single phase, 3 wire, split neutral, 20 spaces and 40 circuits max 1-pole, 10 max 2-pole, 120/240 Volts ac. Factory installed 22,000 AIR main breaker. May be installed on higher rated systems when protected by a circuit breaker feeder with a higher AIR rating. One piece plated aluminum bus bar. 100% circuit breaker twistouts. Positive load side circuit breaker hook rail. When used as service equipment, any unused neutral position may be used for equipment grounding. Rotate entire device 180 degrees for bottom feed. Gray enamel finish. U.L. Listed suitable for use as service equipment, complies fully with NEC and UL requirements for Class CTL. Ten Year limited Warranty. Minimize or Learn More more... |
200 Amp Main Break Load Center
Siemens Energy # G4040B1200
Single phase, 3 wire, split neutral, 40 spaces and 40 circuits max 1-pole max 1-pole, 20 max 2-pole, 120/240 Volts ac. Factory installed 22,000 AIR main breaker. May be installed on higher rated systems when protected by a circuit breaker feeder with a higher AIR rating. Accomodates only full size breakers. One piece plated aluminum bus bar. 100% circuit breaker twistouts. Positive load side circuit breaker hook rail. When used as service equipment, any unused neutral position may be used for equipment grounding. Rotate entire device 180 degrees for bottom feed. Gray enamel finish. U.L. Listed suitable for use as service equipment, complies fully with NEC and UL requirements for Class CTL. Ten Year Limited Warranty. Minimize or Learn More more... |
200 Amp Main Break Load Center
Siemens Energy # G3040B1200
Single phase, 3 wire, split neutral, 30 spaces and 40 circuits max 1-pole, 14 max 2-pole, 120/240 Volts ac. Factory installed 22,000 AIR main breaker. May be installed on higher rated systems when protected by a circuit breaker feeder with a higher AIR rating. One piece plated aluminum bus bar. 100% circuit breaker twistouts. Positive load side circuit breaker hook rail. When used as service equipment, any unused neutral position may be used for equipment grounding. Rotate entire device 180 degrees for bottom feed. Gray enamel finish. U.L. Listed suitable for use as service equipment, complies fully with NEC and UL requirements for Class CTL. Ten Year limited Warranty. Minimize or Learn More more... |
200 Amp Main Breaker 40 Spaces 40 Circuits
Siemens Energy # G4040B1200CP
Single phase, 3 wire, 40 spaces and 40 circuits, 6 single pole breakers and 2 double pole breakers, copper bus, 120/240 Volts ac. 22,000 interrupting capacity. Suitable for use as service entrance equipment. Patented INSTA-Wire allows faster installationbecause screws are back out, ready for wire insertion. Tabs hold the trim in place during installation freeing both hands to drive trim screws. Patented visible neutral bar, which aids in insertion of conductors. Slotted/square drive neutral, trim, upperpan adjusting and bond screws allow increased flexibility. Inboard insulated neutral bars. Pre-positioned bond screw saves installation time and eliminates lost screws. Converts from main breaker to main lug. Rigid positive locking hook rails in molded base pan. Tangential K.O. eliminates the need for conduit offsets U.L. Listed neutral and ground bars that accept multiple ground conductors. Ten year limited warranty. Minimize or Learn More more... |
200 Amp Main Breaker Load Center
GE Electric # TM2020RCU
Single phase, 3 wire, 40 total spaces, 120/240 Volts AC. 20 spaces 1p, 10 spaces 2p max 1" THQL; 40 spaces 1p, 20 spaces 2p max 1/2" THQP. 22,000 AIC. Smaller and lighter box yet maintains optimum wire bending space. Includes tin plated copper bus, galvanized mounting rails, steel studs connect bus bar to main breaker, combo slotted/#2 Robertson screws, 100% neutral terminations, full length split neutral bondable on either side. Furnished with removable closing cap, hubs and No.TGK24 or TGK42 equipmentground kit sold separately. Suitable for use as service entrance equipment when installed in accordance with NEC. 1 - 250 (Cu) or 2/0 - (Al) AWG main lug wire range. U.L. Listed, No.67 Panelboards. Minimize or Learn More more... |
200 Amp Main Breaker Load Center
GE Electric # TM820RCUFLP
Single phase, 3 wire, 16 total 1-pole spaces, 120/240 Volts AC. 8 spaces 1p, 4 spaces 2p max 1"THQL; 16 spaces 1p, 6 spaces 2p max 1/2" THQP 22,000 AIC. Smaller and lighter box yet maintains optimum wire bending space. Additional features including tin-plated copper bus, galvanized mounting rails, steel studs connect bus bar to main breaker, combo slotted/#2 Robertson screws, 100% neutral terminations, full length bondable neutral. Furnished with removable closing cap, hubs and No. TGK24 equipment groundkit sold separately. Suitable for use as service equipment when installed in accordance with the NEC. Factory installed feed-thru lugs. 1 - 250 (Cu) or 2/0 - 250 (A1) AWG main lug wire range. U.L. Listed, No. 67 panelboards. Minimize or Learn More more... |
200 Amp Main Breaker Panel
Cutler-Hammer # CH42B200KP
Single phase, 3 wire, factory bonded split neutral, 42 (3/4") spaces, 42 poles, 120/240 Volts ac. Main breaker type CSR at 25,000 AIC when used with CH, CHT or CHP branch breakers. Solid copper bus bar. Twin neutral with cross bus connecting them. Unusedneutral connections may be used for termination of equipment grounds. Listed for use as service equipment with twin neutral doubling as neutral/ground; remove bonding strap for separate neutral/ground bars for sub-feed applications. Includes combinationsurface/flush cover. #2 - 300 kcmil wire range. Electrostatic powder coat, baked urethane painted sandalwood. Rotate enclosure and trim 180 degrees for bottom feed. Comes with cover and main breaker. U.L. Listed file E8741. Minimize or Learn More more... |
200 Amp Main Breaker Resident Load Center
Cutler-Hammer # BR3040B200
Single phase, 3 wire, insulated/bondable split neutral, 30 (1") spaces, 40 poles, 120/240 Volts ac. Main breaker type BW at 10,000 AIC. Ground bar kit (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. Twin neutral with non-removable cross bus connecting them. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #2 - 300 kcmil wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottomfeed; orientation of main breaker handle consistent with NEC 240-81 requirements because it operates horizontally. U.L. Listed file E52977. Minimize or Learn More more... |
200 Amp Main Breaker Resident Load Center
Cutler-Hammer # BR4040B200
Single phase, 3 wire, insulated/bondable split neutral, 40 (1") spaces, 40 poles, 120/240 Volts ac. Main breaker type BW at 10,000 AIC. Ground bar kit (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. Twin neutral with non-removable cross bus connecting them. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #2 - 300 kcmil wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottomfeed; orientation of main breaker handle consistent with NEC 240-81 requirements because it operates horizontally. U.L. Listed file E52977. Minimize or Learn More more... |
200 Amp Main Lug Indoor Load Center
Cutler-Hammer # BR4040L200
Single phase, 3 wire, insulated/bondable split neutral, 30 (1") spaces, 40 poles, 120/240 Volts AC. Has notch for No.BRHDK125 hold down kit. Ground bar kits (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. Twin neutral with non-removable cross bus connecting them. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #1 - 300 kcmil wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. U.L. Listed file E52977. Minimize or Learn More more... |
200 Amp Main Lug Indoor Load Center
Cutler-Hammer # BR2040L200
Single phase, 3 wire, insulated/bondable split neutral, 20 (1") spaces, 40 poles, 120/240 Volts AC. Has notch for No.BRHDK125 hold down kit. Ground bar kits (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. Twin neutral with non-removable cross bus connecting them. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #1 - 300 kcmil wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. U.L. Listed file E52977. Minimize or Learn More more... |
200 Amp Mainbreaker Load Center
Your One Source # HOM30M200C
Single phase, 3 wire, split neutral, 30 spaces, 30 circuits, 120/240 Volts ac. 10,000 factory AIR installed main breaker, QOM2 main frame size. 3 different mounting locations for ground bar, use No. PK18GTA bar sold separately. Rugged bus bar, slot/square drive screws. Straight in main design. Tangential main service knockouts. Rotate entire device 180 degrees for bottom feed. #4 - 250 kcmil main wire. Gray baked-on enamel finish. U.L. Listed. Minimize or Learn More more... |
200 Amp Mainbreaker Load Center
Your One Source # HOM2040M200TC
Single phase, 3 wire, split neutral, 20 spaces, 40 circuits, 20 tandem breakers accepted, 120/240 Volts ac. 10,000 AIR factory installed main breaker, QOM2 main frame size. 3 different mounting locations for installed ground bar. Rugged bus bar, slot/square drive screws. Straight in main design. Tangential main service knockouts. Rotate entire device 180 degrees for bottom feed. #4 - 250 kcmil main wire. Gray baked-on enamel finish. U.L. Listed. Minimize or Learn More more... |
200 Amp Mobile Home Panels
Siemens Energy # LW204TL
Single phase, 4 spaces, 8 circuits, 120/240 Volts. 10,000 AIR. Factory installed main breaker. Additional spaces allow connection of external circuits such as yard lights. One 2" No.HS200 hub included. Normally used as a means of disconnecting power to amobile home panel, but also used as a disconnect for houses. Aluminum bus bar insulates and secures interior. Drop hinge door. Gray enamel finish. Pole mountable. U.L. Listed for use as service entrance equipment. Minimize or Learn More more... |
Load Center, 200 Amp
Cutler-Hammer # BR4040B200V
Galvanized steel enclosure. Single phase, 3 wire, insulated/bondable split neutral, 40 (1") spaces, 40 circuits, 120/240 volt. Main breaker type BW at 10,000 AIR. Ground bar kit (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. Twin neutral with non-removable cross bus. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #2 - 300 kcmil wire range. Electrostatic powder coat, baked urethane painted. Rotates 180 degrees for bottom feed; orientation of main breaker handle consistent with NEC 240-81 requirements because it operates horizontally. Style L1 Box - 14-5/16" width x 39" height x 3-7/8" depth. UL Listed file E52977. Minimize or Learn More more... |
Load Center, 200 Amp
Cutler-Hammer # BR3040B200V
Galvanized steel enclosure. Single phase, 3 wire, insulated/bondable split neutral, 30 (1") spaces, 40 poles, 120/240 volt. Main breaker type BW at 10,000 AIR. Ground bar kit (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. Twin neutral with non-removable cross bus. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #2 - 300 kcmil wire range. Electrostatic powder coat, baked urethane painted. Rotates 180 degrees for bottom feed; orientation of main breaker handle consistent with NEC 240-81 requirements because it operates horizontally. G1 Box - 14-5/16" width x 34-1/8" height x 3-7/8" depth. UL Listed file E52977. Minimize or Learn More more... |