125 Amp Indoor Load Center
Your One Source # HOM20L125C
Single phase, 3 wire, split neutral, 20 spaces, 20 circuits, 120/240 Volts AC. No.PK15GTA ground bar sold separately. Slot/square drive screws, 3 ground bar mounting locations. Straight in main design. Tangential main service knockouts. #4 - 2/0 AWG mainwire. Rotate 180 degrees for bottom feed. U.L. Listed. QOMA1 Main Frame Size: Convertible to 22,000 AIR main breaker with No.QOM125VHCP main circuit breaker for 125 amp frame, #4 - 2/0 AWG main wire size. Minimize or Learn More more... |
125 Amp Indoor Load Centers
GB Electrical # TL412C
Single phase, 3 wire, 8 total 1-pole spaces, 120/240 Volts AC. 4 spaces 1p, 2 spaces 2p max 1" THQL; 8 spaces 1p , 3 spaces 2p max 1/2" THQP. 10,000 AIC, no door. No.TGL1 equipment ground kit sold separately. Suitable for use as service equipment when installed in accordance with the NEC. 1 - 2/0 AWG main lug wire range. U.L. Listed for bottom mounted lugs by installing complete unit upside down, No.TRL22B bottom feed door handle not included. U.L. Listed, No.67 panelboards. Minimize or Learn More more... |
125 Amp Main Lug Indoor Load Center
Cutler-Hammer # BR816L125SDP
Single phase, 3 wire, insulated/bondable neutral, 8 (1") spaces, 16 poles, 120/240 Volts AC. Furnished with door; No.GBK10 ground bar sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when a mainbreaker is used or when not more than 6 service disconnecting mains are provided and when not used as a lighting or appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectorsin service entrance application. #14-#1 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees bottom feed. U.L. Listed file E8741. Minimize or Learn More more... |
125 Amp Main Lug Indoor Load Center
Cutler-Hammer # BR2024L125
Single phase, 3 wire, insulated/bondable split neutral, 20 (1") spaces, 24 poles, 120/240 Volts AC. Has notch for No.BREQS125 hold down kit. Ground bar kits (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. Twin neutral with non-removable cross bus connecting them. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #6 - 2/0 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottomfeed. U.L. Listed file E52977. Minimize or Learn More more... |
125 Amp Main Lug Indoor Load Center
Cutler-Hammer # BR1224L125P
Single phase, 3 wire, insulated/bondable split neutral, 12 (1") spaces, 24 poles, 120/240 Volts AC. Has notch for No.BREQS125 hold down kit. Ground bar kits (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. In accordance with NEC,suitable for use as service equipment when not more than 6 main disconnecting means are provided and when not used as a lighting and appliance panelboard. Twin neutral with non-removable cross bus connecting them. When bonded, unused neutral connectionsmay be used for equipment ground protectors in service entrance application. #6 - 2/0 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. U.L. Listed file E52977 Minimize or Learn More more... |
125 Amp Main Lug Indoor Load Center
Your One Source # HOM816L125C
Single phase, 3 wire, split neutral, 8 spaces, 16 circuits, 8 tandem breakers accepted, 120/240 Volts AC. No.PK15GTA ground bar sold separately. Slot/square drive screws, 3 ground bar mounting locations. Straight in main design. Tangential main service knockouts. #4 - 2/0 AWG main wire. Rotate 180 degrees for bottom feed. U.L. Listed. QOMA1 Main Frame Size: Convertible to 22,000 AIR main breaker with No.QOM125VHCP main circuit breaker for 125 amp frame, #4 - 2/0 AWG main wire size. Minimize or Learn More more... |
125 Amp Main Lug Load Center
Siemens Energy # W0816ML1125CU
Single phase, 3 wire, solid neutral, 8 spaces/16 circuits 1-pole, 4 QP breakers 2-pole, 120/240 Volts AC. 10,000 AIR. HS-hubs sold separately. One piece copper bus bar, 100% circuit breaker twistouts. Positive load side circuit breaker hook rail. Suitable for use as service equipment when a main breaker (125 amp max) is back-fed in a branch position, and used with main breaker retainer clip No. MBR1. When used as service equipment, any unused neutral position may be used for equipment grounding. Rotate entire device 180 degrees for bottom feed. Gray enamel finish. CSA and U.L. Listed, complies fully with NEC and U.L. requirements for Class CTL. Ten Year Limited Warranty. Minimize or Learn More more... |
125 Amp Main Lug Load Center
Siemens Energy # E0408ML1125SU
Single phase, 3 wire, solid neutral, 4 spaces and 8 circuits max 1-pole, 2 QP breakers max 2-pole, 120/240 Volts AC. 10,000 AIR. One piece plated aluminum bus bar. 100% circuit breaker twistouts. Positive load side circuit breaker hook rail. Suitable foruse as service equipment when a main breaker (100 amp max) is back-fed in a branch position and used with main breaker retainer clip No.MBR1. When used as service equipment, any unused neutral position may be used for equipment grounding. Rotate entire device 180 degrees for bottom feed. Gray enamel finish. CSA and U.L. Listed, complies fully with NEC and U.L. requirements for Class CTL. Ten Year Limited Warranty. Minimize or Learn More more... |
125 Amp Main Lug Load Center
Siemens Energy # E0816ML1125S
Single phase, 3 wire, solid neutral, 8 spaces and 16 circuits max 1-pole, 4 QP breakers max 2-pole, 120/240 Volts AC. 10,000 AIR. One piece plated aluminum bus bar. 100% circuit breaker twistouts. Positive load side circuit breaker hook rail. Suitable for use as service entrance equipment when a main breaker (125 amp max) is back-fed in branch position and used with main breaker retainer clip No.MBR1. When used as service equipment, any unused neutral position may be used for equipment grounding. Rotateentire device 180 degrees for bottom feed. Gray enamel finish. CSA and U.L. Listed, complies fully with NEC and U.L. requirements for Class CTL. Ten Year Limited Warranty. Minimize or Learn More more... |
125 Amp Main Lug Load Center
Siemens Energy # W0408ML1125U
Single phase, 3 wire, solid neutral, 4 spaces/8 circuits 1-pole, 2 QP breakers 2-pole, 120/240 Volts AC. 10,000 AIR. With closure plates, HS-hubs sold separately. One piece plated aluminum bus bar. 100% circuit breaker twistouts. Positive load side circuit breaker hook rail. Suitable for use as service equipment when a main breaker (100 amp max) is back-fed in a branch position and used with main breaker retainer clip No.MBR1. When used as service equipment, any unused neutral position may be used for equipment grounding. Rotate entire device 180 degrees for bottom feed. Gray enamel finish. CSA and U.L. Listed, complies fully with NEC and U.L. requirements for Class CTL. Ten Year Limited Warranty. Minimize or Learn More more... |
125 Amp Main Lug Load Center
Cutler-Hammer # BR612L125RP
Single phase, 3 wire, insulated/bondable movable neutral, 6 (1") spaces, 12 poles, 120/240 Volts AC. With closure plates, hubs and No.GBK10 ground bar kits (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. In accordance with NEC,suitable for use as service equipment when a main breaker is used or when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. When bonded, unused neutral connections may be used for equipmentground protectors in service entrance application. #14-#1 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. U.L. Listed file E8741. Minimize or Learn More more... |
125 Amp Main Lug Load Center
Cutler-Hammer # BR816L125RP
Single phase, 3 wire, insulated/bondable movable neutral, 8 (1") spaces, 16 poles, 120/240 Volts AC. With closure plates, hubs and No.GBK10 ground bar kits (necessary for sub-feeding sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when a main breaker is used or when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #14-#1 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. U.L. Listed file E8741. Minimize or Learn More more... |
125 Amp Main Lug Load Center
Your One Source # HOM816L125RB
Single phase, 3 wire solid neutral. 8 spaces, 16 circuits, 8 tandem breakers accepted, 120/240 Volts AC. 10,000 AIR. Factory installed main lugs. Furnished with removable closing cap covering 2" bushed opening, B-hubs and No.PK15GTA ground bar sold separately. Slot/square drive screws. Straight in main design. #4 - 2/0 AWG main wire. Rotate 180 degrees for bottom feed. U.L. Listed. QOM1 Main Frame Size: Convertible to 22,000 AIR main breaker with No.QOM125VHCP main circuit breaker for 125 amp frame. Minimize or Learn More more... |
125 Amp Main Lug Load Center
Cutler-Hammer # BR48L125FP
Single phase, 3 wire, insulated/bondable neutral, 4 (1") spaces, 8 poles, 120/240 Volts AC. No.GBK10 ground bars and doors sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in service application. #14 - 1/0 AWG wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. U.L. Listed file E8741. Minimize or Learn More more... |
125 Amp Main Lug Load Center
Cutler-Hammer # BR48L125RP
Single phase, 3 wire, insulated/bondable movable neutral, 4 (1") spaces, 8 poles, 120/240 Volts AC. With closure plates, hubs, and No.GBK10 ground bar kits (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. In accordance with NEC,suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #14-1/0 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. U.L. Listed file E8741. Minimize or Learn More more... |
125 Amp Main Lug Panel
Cutler-Hammer # BR816L125FP
Single phase, 3 wire, insulated/bondable neutral, 8 (1") spaces, 16 poles, 120/240 Volts AC. No.GBK10 ground bar and door sold separatelt. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when a main breaker is used or when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in serviceentrance application. #14 - #1 AWG wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. U.L. Listed file E8741. Minimize or Learn More more... |
125 Amp Main Lug Panel
Cutler-Hammer # BR612L125SP
Single phase, 3 wire, insulated/bondable neutral, 6 (1") spaces, 12 poles, 120/240 Volts AC. No.GBK10 ground bar and door sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when a main breaker is used or when not more than 6 service disconnecting mains are provided and when not used as a lighting and appliance panelboard. Neutral is movable to other side. When bonded, unused neutral connections may be used for equipment ground protectors in serviceentrance appliance. #14 - #1 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. U.L. Listed file E8741. Minimize or Learn More more... |
125 Amp Main Lug Panel Enclosed
Cutler-Hammer # BR24L125RP
Single phase, 3 wire, insulated/bondable movable neutral, 2 (1") spaces, 4 poles, 120/240 Volts AC. With closure plates, hubs and No.GBK5 or GBK520 ground bar kits (necessary for sub-feeding) sold separately. Tin-plated aluminum bus bar. In accordance with NEC, suitable for use as service equipment when not more than 2 service disconnecting mains are provided or when not used as a lighting and appliance panelboard. When bonded, unused neutral connections may be used for equipment ground protectors in service entrance application. #14-1/0 wire range. Electrostatic powder coat, baked urethane painted. Rotate 180 degrees for bottom feed. U.L. Listed file E8741. Minimize or Learn More more... |
125 Amp Rainproof Load Center
GB Electrical # TLM1212RCU
Single phase, 3 wire, 24 total 1-pole spaces, 120/240 Volts AC. 12 spaces 1p, 6 spaces 2p max 1" THQL; 24 spaces 1p, 10 spaces 2p max 1/2" THQP. 22,000 AIC. Smaller and lighter box yet maintains optimum wire bending space. Additional features including tin-plated copper bus, galvanized mounting rails, combo slotted/#2 Robertson screws, 100% neutral terminations, full length split neutral bondable on either side, remove tie bar to split neutral/ground. With removable closing cap, hubs and No.TGK12 equipment ground kit sold separately. Suitable for use as service equipment when installed in accordance with the NEC. 6-2/0 AWG main lug wire range. Bottom feed entrance by running wire on side. U.L. Listed, No.67 panelboards. For converting to main breaker use No. TQMH000 and THQL, THHQL or TXQL 2-pole circuit breaker, or conversion kit No. THQMH100CP for 100 amp/No. THQMH125CP for 125 amp (not included). Minimize or Learn More more... |
125 Amp Spa Panel with 50 Amp 2 Pole GFI
GB Electrical # UG412RMW250
Single phase, 2 or 4 breaker spaces. 50 amp GFI protection rating. Moisture resistant use around water heaters, swimming pools, spas, hot tubs, garden tubs, and pools, etc. Includes 2 pole 50 amp ground fault breaker. Minimize or Learn More more... |
125 Amp Surface Mount Load Center
GB Electrical # TL412R1
Single phase, 3 wire, 8 total 1-pole spaces, 120/240 Volts AC. 4 spaces 1p, 2 spaces 2p max 1" THQL: 8 spaces 1p, 3 spaces 2p max 1/2" THQP. 10,000 AIC. Furnished with removable closing cap, hubs and No. TGL1 equipment ground kit sold separately. Suitable for use as service equipment when installed in accordance with the NEC. 1-2/0 AWG main lug wire range. Bottom feed entrance is available by running wire on side. U.L. Listed, No. 67 panelboards. Minimize or Learn More more... |