
Clamp Connector For Non-Metallic Cable, 3/4"
Halex # 05107B
Indoors Only. Fits NM Cable: #14/2 Round, #12/3-8/3 AWG or Flex cord .460 to .720 inches diameter 3/8" (1/2ko). Type: Twin Screw. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. Miscellaneous: 1/2" knockout. Minimize or Learn More more... |
Clamp Connector, 3/8"
Halex # 05103B
Zinc die cast. In a dry location, use to connect non-metallic sheathed cable to a steel outlet box, load center or other metal enclosure. 3/8" size fits 1/2" knock out Nos. 05103, 90510, 20510, 20517, and 40510 - Fits NM cable #14/2, #12/2. Nos. 05107, 90512, and 40512 - Fits NM cable #12-3, #10-3, #8-2; SE cable #10-3, #6-2, #6-3, #4-2, #2-2. Nos. 05110, 90513, and 40513 - Fits NM cable #12-3, #12-4, #10-3, #10-4, #8-3, #8-2, #6-2, #4-2; SE cable #6-3, #4-3, #4-0, #2-2. Nos. 05112, 90514, and 40514 - Fits NM cable #8-3, #6-3, #4-3, #2-3; SE cable #10-2, #8-2, #6-2, #4-2. Nos. 05115, and 90515 - Fits NM cable. 0.800" diameter - 1.350" diameter; SE cable #3-3, #3-2, #3-1. Nos. 05120 Fits NM cable. 0.800" diameter - 1.350" diameter; SE cable #3-4/0. Minimize or Learn More more... |
EMT 90° Connector, 1/2"
Halex # 11005B
Indoors Only. In a dry location, use to connect flexible metal conduit, aluminum and steel AC and MC cable to a steel outlet box or other metal enclosure. Miscellaneous: 3/8" size fits 1/2" knockout. Suitable For: 3/8" - 3/4" steel and aluminum armored cable, steel and aluminum interlocked metal clad cable, flexible cord, and flexible metal conduit. 1" - 4" flexible metal conduit. Minimize or Learn More more... |
EMT Conduit Nipple, 1/2"
Halex # 07005B
Indoors or Outdoors. Use with a rigid coupling to terminate threaded conduit to a knockout box or enclosure, where space within the box is limited. Used with a locknut to provide a short raceway between boxes or enclosures. Minimize or Learn More more... |
EMT Screw Connector, 3/4"
Halex # 12107B
Indoors Only. Use to connect EMT conduit to steel outlet box, load center, or other metal enclosure. Features: Concrete-Tight 1/2"-3/4", Concrete-Tight when taped 1"-4". Minimize or Learn More more... |
EMT Set Screw Connector, 1/2"
Halex # 12105B
Indoors Only. Use to connect EMT conduit to steel outlet box, load center, or other metal enclosure. Features: Concrete-Tight 1/2"-3/4", Concrete-Tight when taped 1"-4". Minimize or Learn More more... |
UF Cable Watertight Connector, 3/4"
Halex # 06607B
Indoors or Outdoors. Fits UF Cable Only: #12/2, #12/3. Use to secure SE/SEU cable to a metal enclosure. Use to connect UF cable to a waterproof box with threaded hub. Purpose: for UF cable; two insulating conductors, one bare. Minimize or Learn More more... |
Box Spacer, 3/4"
Halex # 16407B
Zinc die cast. Use as a raceway between two steel outlet boxes or other metal enclosures. U.L. Listed. Minimize or Learn More more... |
Clamp Connector, 1"
Halex # 90513
Zinc die cast. In a dry location, use to connect non-metallic sheathed cable to a steel outlet box, load center or other metal enclosure. 3/8" size fits 1/2" knock out Nos. 05103, 90510, 20510, 20517, and 40510 - Fits NM cable #14/2, #12/2. Nos. 05107, 90512, and 40512 - Fits NM cable #12-3, #10-3, #8-2; SE cable #10-3, #6-2, #6-3, #4-2, #2-2. Nos. 05110, 90513, and 40513 - Fits NM cable #12-3, #12-4, #10-3, #10-4, #8-3, #8-2, #6-2, #4-2; SE cable #6-3, #4-3, #4-0, #2-2. Nos. 05112, 90514, and 40514 - Fits NM cable #8-3, #6-3, #4-3, #2-3; SE cable #10-2, #8-2, #6-2, #4-2. Nos. 05115, and 90515 - Fits NM cable. 0.800" diameter - 1.350" diameter; SE cable #3-3, #3-2, #3-1. Nos. 05120 Fits NM cable. 0.800" diameter - 1.350" diameter; SE cable#3-4/0. Minimize or Learn More more... |
Conduit Chase Nipple, 1/2"
Halex # 07012
Use to terminate to a knockout box or enclosure, where space within the box is limited. Used with a locknut to provide a short raceway between boxes or enclosures. CSA, U.L. Approved. Minimize or Learn More more... |
Conduit Chase Nipple, 3/4"
Halex # 90702
Zinc die cast. Indoor or outdoor applications. Use to terminate threaded conduit to a knockout box or enclosure, where space within the box is limited. Used with a locknut to provide a short raceway between boxes or enclosures. U.L. Approved. Minimize or Learn More more... |
Conduit Nipple, 2 1/2"
Halex # 07025B
Zinc die cast. Indoor or outdoor applications. Use to terminate threaded conduit to a knockout box or enclosure, where space within the box is limited. Used with a locknut to provide a short raceway between boxes or enclosures. U.L. Approved. Minimize or Learn More more... |
Conduit Nipple, 2"
Halex # 07020
Zinc die cast. Indoor or outdoor applications. Use to terminate threaded conduit to a knockout box or enclosure, where space within the box is limited. Used with a locknut to provide a short raceway between boxes or enclosures. U.L. Approved. Minimize or Learn More more... |
EMT Compression Connector, 1 1/4"
Halex # 02112
Zinc die cast. Use to connect E.M.T. conduit to steel outlet box, load center or other metal enclosure. U.L. Approved. Minimize or Learn More more... |
EMT Compression Connector, 1"
Halex # 02110
Zinc die cast. Use to connect E.M.T. conduit to steel outlet box, load center or other metal enclosure. U.L. Approved. Minimize or Learn More more... |
EMT Compression Connector, 1-1/2"
Halex # 02115
Zinc die cast. Use to connect E.M.T. conduit to steel outlet box, load center or other metal enclosure. U.L. Approved. Minimize or Learn More more... |
EMT Compression Connector, 1/2"
Halex # 02105B
Zinc die cast. Use to connect E.M.T. conduit to steel outlet box, load center or other metal enclosure. U.L. Approved. Minimize or Learn More more... |
EMT Compression Connector, 1/2"
Halex # 90211
Zinc die cast. Use to connect E.M.T. conduit to steel outlet box, load center or other metal enclosure. U.L. Approved. Minimize or Learn More more... |
EMT Compression Connector, 3/4"
Halex # 02107B
Zinc die cast. Use to connect E.M.T. conduit to steel outlet box, load center or other metal enclosure. U.L. Approved. Minimize or Learn More more... |
EMT Compression Connector, 3/4"
Halex # 90212
Zinc die cast. Use to connect E.M.T. conduit to steel outlet box, load center or other metal enclosure. U.L. Approved. Minimize or Learn More more... |
EMT Offset Connector, 1/2"
Halex # 90371
Zinc die cast. Use to connect E.M.T. conduit to a metal outlet box or enclosure where an offset is desired. U.L. Approved. Minimize or Learn More more... |
EMT Offset Connector, 3/4"
Halex # 90372
Zinc die cast. Use to connect E.M.T. conduit to a metal outlet box or enclosure where an offset is desired. U.L. Approved. Minimize or Learn More more... |
EMT Set Screw Connector, 1 1/4"
Halex # 12112
Zinc die cast. Use to connect E.M.T. conduit to steel outlet box, load center or other metal enclosure. U.L. Approved. Minimize or Learn More more... |
EMT Set Screw Connector, 1"
Halex # 12110
Zinc die cast. Use to connect E.M.T. conduit to steel outlet box, load center or other metal enclosure. U.L. Approved. Minimize or Learn More more... |
EMT Set Screw Connector, 1/2"
Halex # 91211
Zinc die cast. Use to connect E.M.T. conduit to steel outlet box, load center or other metal enclosure. U.L. Approved. Minimize or Learn More more... |
EMT Set Screw Connector, 1/2"
Halex # 21210
Zinc die cast. Use to connect E.M.T. conduit to steel outlet box, load center or other metal enclosure. U.L. Approved. Minimize or Learn More more... |
EMT Set Screw Connector, 2"
Halex # 12120
Zinc die cast. Use to connect E.M.T. conduit to steel outlet box, load center or other metal enclosure. U.L. Approved. Minimize or Learn More more... |
EMT Set Screw Connector, 3/4"
Halex # 91212
Zinc die cast. Use to connect E.M.T. conduit to steel outlet box, load center or other metal enclosure. U.L. Approved. Minimize or Learn More more... |
EMT Set Screw Connector, 3/4"
Halex # 12107B
Zinc die cast. Use to connect E.M.T. conduit to steel outlet box, load center or other metal enclosure. U.L. Approved. Minimize or Learn More more... |
EMT Set Screw Connector, 3/4"
Halex # 21212
|
EMT Set Screw Connectors, 1/2"
Halex # 12105B
Zinc die cast. Use to connect E.M.T. conduit to steel outlet box, load center or other metal enclosure. U.L. Approved. Minimize or Learn More more... |
EMT Set Screw Offset Connector, 3/4"
Halex # 03707B
Zinc die cast. Use to connect E.M.T. conduit to a metal outlet box or enclosure where an offset is desired. U.L. Approved. Minimize or Learn More more... |
EMT Snap N Set Screw Connector, 1/2"
Halex # 12005B
Zinc die cast. Use to connect E.M.T conduit to steel outlet box, load center of other metal enclosure. U.L. Approved. Minimize or Learn More more... |
EMT Snap N Set Screw Connector, 3/4"
Halex # 12007B
Zinc die cast. Use to connect E.M.T conduit to steel outlet box, load center of other metal enclosure. U.L. Approved. Minimize or Learn More more... |
Flex Box Connector, 3/4"
Halex # 91102
Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to a steel outlet box or other metal enclosure. 3/8" size fits 1/2" K.O. Minimize or Learn More more... |
Flex Box Screw In Connector, 1/2"
Halex # 90441
Zinc die cast. Use to connect flexible metallic conduit (Greenfield) to steel outlet box, load center or other metal enclosure. 3/8" size fits 1/2" K.O. Minimize or Learn More more... |
Flex Box Screw In Connector, 3/4"
Halex # 90442
Zinc die cast. Use to connect flexible metallic conduit (Greenfield) to steel outlet box, load center or other metal enclosure. 3/8" size fits 1/2" K.O. Minimize or Learn More more... |
Flex Box Screw In Connector, 3/8"
Halex # 90440
Zinc die cast. Use to connect flexible metallic conduit (Greenfield) to steel outlet box, load center or other metal enclosure. 3/8" size fits 1/2" K.O. Minimize or Learn More more... |
Flex Box Squeeze Connector, 1 1/4"
Halex # 04212
Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to steel outlet box, load center or other metal enclosure. 3/8" size fits 1/2" knock outs. U.L. Approved. Minimize or Learn More more... |
Flex Box Squeeze Connector, 1"
Halex # 4210
Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to steel outlet box, load center or other metal enclosure. 3/8" size fits 1/2" K.O. U.L. Approved. Minimize or Learn More more... |
Flex Box Squeeze Connector, 1/2"
Halex # 90421
Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to steel outlet box, load center or other metal enclosure. 3/8" size fits 1/2" K.O. U.L. Approved. Minimize or Learn More more... |
Flex Box Squeeze Connector, 1/2"
Halex # 04205B
Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to steel outlet box, load center or other metal enclosure. 3/8" size fits 1/2" K.O. U.L. Approved. Minimize or Learn More more... |
Flex Box Squeeze Connector, 3/4"
Halex # 04207B
Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to steel outlet box, load center or other metal enclosure. 3/8" size fits 1/2" K.O. U.L. Approved. Minimize or Learn More more... |
Flex Box Squeeze Connector, 3/4"
Halex # 90422
Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to steel outlet box, load center or other metal enclosure. 3/8" size fits 1/2" K.O. U.L. Approved. Minimize or Learn More more... |
Flex Box Squeeze Connector, 3/8"
Halex # 90420
Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to steel outlet box, load center or other metal enclosure. 3/8" size fits 1/2" K.O. U.L. Approved. Minimize or Learn More more... |
Flex Box Squeeze Connector, 3/8"
Halex # 04203B
Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to steel outlet box, load center or other metal enclosure. 3/8" size fits 1/2" K.O. U.L. Approved. Minimize or Learn More more... |
Flex Connector, 1/2" 90 Deg
Halex # 91101
Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to a steel outlet box or other metal enclosure. 3/8" size fits 1/2" K.O. Minimize or Learn More more... |
Flex Connector, 3/8" 90 Deg
Halex # 91100
Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to a steel outlet box or other metal enclosure. 3/8" size fits 1/2" K.O. Minimize or Learn More more... |
Flex Set Screw Connector, 1/2"
Halex # 90481
Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to a steel outlet box or other metal enclosure. U.L. Approved. Minimize or Learn More more... |
Flexible BX Cable Connector, 3/8"
Halex # 05803B
Zinc die cast. In a dry location, use to connect BX cable to a steel outlet box or other metal enclosure. 3/8" size fits 1/2" K.O. U.L. Approved. Minimize or Learn More more... |
Liquid Tigh Connecor, 1 1/2"
Halex # 16215B
Multi-piece. Zinc die cast. 3/8" size fits 1/2" knock outs. Use to connect liquid-tight conduit to a steel outlet box or other metal enclosure or hub. U.L. Listed. Minimize or Learn More more... |
Liquid Tight Carflex Connector, 1/2"
Carlon Home Products # LN43DA-CTN
For flexible conduit. Non-metallic/non-conductive, corrosion resistant plastic. Easy to install. Minimize or Learn More more... |
Liquid Tight Connector, 1 1/4"
Halex # 16212B
Multi-piece. Zinc die cast. 3/8" size fits 1/2" knock outs. Use to connect liquid-tight conduit to a steel outlet box or other metal enclosure or hub. U.L. Listed. Minimize or Learn More more... |
Liquid Tight Connector, 1/2"
Halex # 16205B
Multi-piece. Zinc die cast. 3/8" size fits 1/2" K.O. Use to connect liquid-tight conduit to a steel outlet box or other metal enclosure or hub. U.L. Listed. Minimize or Learn More more... |
Liquid Tight Connector, 1/2"
Halex # 91625
Zinc die cast. Use to connect liquid-tight conduit to a steel outlet box or other metal enclosure or hub. U.L. Approved. Minimize or Learn More more... |
Liquid Tight Connector, 2"
Halex # 16220B
Multi-piece. Zinc die cast. 3/8" size fits 1/2" K.O. Use to connect liquid-tight conduit to a steel outlet box or other metal enclosure or hub. U.L. Listed. Minimize or Learn More more... |
Liquid Tight Connector, 3/4"
Halex # 16207B
Multi-piece. Zinc die cast. 3/8" size fits 1/2" K.O. Use to connect liquid-tight conduit to a steel outlet box or other metal enclosure or hub. U.L. Listed. Minimize or Learn More more... |
Liquid Tight Connector, 3/4"
Halex # 91697
Zinc die cast material. 3/8" size fits 1/2" knockout. Minimize or Learn More more... |
Liquid Tight Connector, 3/4"
Halex # 91627
Zinc die cast. Use to connect liquid-tight conduit to a steel outlet box or other metal enclosure or hub. U.L. Approved. Minimize or Learn More more... |
Non Metallic 2Pc Clamp Connector, 3/4-1"
Halex # 26512
Zinc die cast. In a dry location, use to secure #14 - #10 non-metallic sheathed cable to steel outlet box or other metal enclosure. No locknut required. 3/8" size fits 1/2" K.O. Minimize or Learn More more... |
Non Metallic 2Pc Clamp Connector, 3/8"
Halex # 96510
Zinc die cast. In a dry location, use to secure #14 - #10 non-metallic sheathed cable to steel outlet box or other metal enclosure. No locknut required. 3/8" size fits 1/2" K.O. Minimize or Learn More more... |
Non Metallic Clamp Connector, 3/8"
Halex # 20511
Use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. Zinc die cast. Minimize or Learn More more... |
Non Metallic SE Clamp Connector, 1 1/2"
Halex # 5115
Zinc die cast. In a dry location, use to connect non-metallic sheathed cable to a steel outlet box, load center or other metal enclosure. 3/8" size fits 1/2" K.O. Nos. 05103, 90510, 20510, 20517, and 40510 - Fits NM cable #14/2, #12/2. Nos. 05107, 90512,and 40512 - Fits NM cable #12-3, #10-3, #8-2; SE cable #10-3, #6-2, #6-3, #4-2, #2-2. Nos. 05110, 90513, and 40513 - Fits NM cable #12-3, #12-4, #10-3, #10-4, #8-3, #8-2, #6-2, #4-2; SE cable #6-3, #4-3, #4-0, #2-2. Nos. 05112, 90514, and 40514 - Fits NMcable #8-3, #6-3, #4-3, #2-3; SE cable #10-2, #8-2, #6-2, #4-2. Nos. 05115, and 90515 - Fits NM cable. 0.800" diameter - 1.350" diameter; SE cable #3-3, #3-2, #3-1. Nos. 05120 Fits NM cable. 0.800" diameter - 1.350" diameter; SE cable #3-4/0. Minimize or Learn More more... |
Non Metallic SE Clamp Connector, 1 1/4"
Halex # 90514
Zinc die cast. In a dry location, use to connect non-metallic sheathed cable to a steel outlet box, load center or other metal enclosure. 3/8" size fits 1/2" K.O. Nos. 05103, 90510, 20510, 20517, and 40510 - Fits NM cable #14/2, #12/2. Nos. 05107, 90512,and 40512 - Fits NM cable #12-3, #10-3, #8-2; SE cable #10-3, #6-2, #6-3, #4-2, #2-2. Nos. 05110, 90513, and 40513 - Fits NM cable #12-3, #12-4, #10-3, #10-4, #8-3, #8-2, #6-2, #4-2; SE cable #6-3, #4-3, #4-0, #2-2. Nos. 05112, 90514, and 40514 - Fits NMcable #8-3, #6-3, #4-3, #2-3; SE cable #10-2, #8-2, #6-2, #4-2. Nos. 05115, and 90515 - Fits NM cable. 0.800" diameter - 1.350" diameter; SE cable #3-3, #3-2, #3-1. Nos. 05120 Fits NM cable. 0.800" diameter - 1.350" diameter; SE cable #3-4/0. Minimize or Learn More more... |
Non Metallic SE Clamp Connector, 3/4"
Halex # 90512
Zinc die cast. In a dry location, use to connect non-metallic sheathed cable to a steel outlet box, load center or other metal enclosure. 3/8" size fits 1/2" K.O. Nos. 05103, 90510, 20510, 20517, and 40510 - Fits NM cable #14/2, #12/2. Nos. 05107, 90512,and 40512 - Fits NM cable #12-3, #10-3, #8-2; SE cable #10-3, #6-2, #6-3, #4-2, #2-2. Nos. 05110, 90513, and 40513 - Fits NM cable #12-3, #12-4, #10-3, #10-4, #8-3, #8-2, #6-2, #4-2; SE cable #6-3, #4-3, #4-0, #2-2. Nos. 05112, 90514, and 40514 - Fits NMcable #8-3, #6-3, #4-3, #2-3; SE cable #10-2, #8-2, #6-2, #4-2. Nos. 05115, and 90515 - Fits NM cable. 0.800" diameter - 1.350" diameter; SE cable #3-3, #3-2, #3-1. Nos. 05120 Fits NM cable. 0.800" diameter - 1.350" diameter; SE cable #3-4/0. Minimize or Learn More more... |
Non Metallic SE Clamp Connector, 3/8"
Halex # 90510
Zinc die cast. In a dry location, use to connect non-metallic sheathed cable to a steel outlet box, load center or other metal enclosure. 3/8" size fits 1/2" K.O. Nos. 05103, 90510, 20510, 20517, and 40510 - Fits NM cable #14/2, #12/2. Nos. 05107, 90512,and 40512 - Fits NM cable #12-3, #10-3, #8-2; SE cable #10-3, #6-2, #6-3, #4-2, #2-2. Nos. 05110, 90513, and 40513 - Fits NM cable #12-3, #12-4, #10-3, #10-4, #8-3, #8-2, #6-2, #4-2; SE cable #6-3, #4-3, #4-0, #2-2. Nos. 05112, 90514, and 40514 - Fits NMcable #8-3, #6-3, #4-3, #2-3; SE cable #10-2, #8-2, #6-2, #4-2. Nos. 05115, and 90515 - Fits NM cable. 0.800" diameter - 1.350" diameter; SE cable #3-3, #3-2, #3-1. Nos. 05120 Fits NM cable. 0.800" diameter - 1.350" diameter; SE cable #3-4/0. Minimize or Learn More more... |
Non-Metallic Clamp On Connector, 2"
Halex #
Fits non metallic cable, flex cords, multi flex cords fitting range 1.085 - 1.520 inches diameter. With 1/2" knockout. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. UL Listed, meets CSA requir Minimize or Learn More more... |
Rigid Box Spacer, 1/2"
Halex # 91641
Die cast of high strength zinc alloy. Locknut is reversible. It is designed to cut through protective coatings on boxes and enclosures to assure ground continuity. UL and CSA listed. Corrosion resistant. Minimize or Learn More more... |
Rigid Box Spacer, 1/2"
Halex # 16405B
Zinc die cast. Use as a raceway between two steel outlet boxes or other metal enclosures. U.L. Listed. Minimize or Learn More more... |
Rigid Conduit Chase Nipple, 1/2"
Halex # 90701
Zinc die cast. Indoor or outdoor applications. Use to terminate threaded conduit to a knockout box or enclosure, where space within the box is limited. Used with a locknut to provide a short raceway between boxes or enclosures. U.L. Approved. Minimize or Learn More more... |
Rigid Conduit Chase Nipple, 1/2"
Halex # 07015
Use to terminate to a knockout box or enclosure, where space within the box is limited. Used with a locknut to provide a short raceway between boxes or enclosures. CSA, U.L. Approved. Minimize or Learn More more... |
Rigid T Conduit Body, 1"
Halex # 58810
|
Rigid Water Tight Conduit Hub Connector, 2"
Halex # 16320
Connect rigid or IMC conduit to a load center or other metal enclosure where a weathertight joint is required. Rain, oil amd dust tight. Zinc die-cast, flame retardent Lexan throat. Minimize or Learn More more... |
Romex Flex Connector, 3/8" 90 Degrees
Halex # 11003B
Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to a steel outlet box or other metal enclosure. 3/8" size fits 1/2" knock outs. Minimize or Learn More more... |
Set Screw Connector, 1 1/2" EMT
Halex # 12115
Zinc die cast. Use to connect E.M.T. conduit to steel outlet box, load center or other metal enclosure. U.L. Approved. Minimize or Learn More more... |
Set Screw Type Offset Connector, 1/2" EMT
Halex # 03705B
Zinc die cast. Use to connect E.M.T. conduit to a metal outlet box or enclosure where an offset is desired. U.L. Approved. Minimize or Learn More more... |
Twin Screw Connectors, 1 1/4"
Halex # 05112B
Zinc die cast. In a dry location, use to connect non-metallic sheathed cable to a steel outlet box, load center or other metal enclosure. 3/8" size fits 1/2" K.O. Nos. 05103, 90510, 20510, 20517, and 40510 - Fits NM cable #14/2, #12/2. Nos. 05107, 90512,and 40512 - Fits NM cable #12-3, #10-3, #8-2; SE cable #10-3, #6-2, #6-3, #4-2, #2-2. Nos. 05110, 90513, and 40513 - Fits NM cable #12-3, #12-4, #10-3, #10-4, #8-3, #8-2, #6-2, #4-2; SE cable #6-3, #4-3, #4-0, #2-2. Nos. 05112, 90514, and 40514 - Fits NMcable #8-3, #6-3, #4-3, #2-3; SE cable #10-2, #8-2, #6-2, #4-2. Nos. 05115, and 90515 - Fits NM cable. 0.800" diameter - 1.350" diameter; SE cable #3-3, #3-2, #3-1. Nos. 05120 Fits NM cable. 0.800" diameter - 1.350" diameter; SE cable #3-4/0. Minimize or Learn More more... |
Water Tight Connector Hub, 1 1/2"
Halex # 16315
Connect rigid or IMC conduit to a load center or other metal enclosure where a weathertight joint is required. Rain, oil amd dust tight. Zinc die-cast, flame retardent Lexan throat. Minimize or Learn More more... |
Water Tight Connector, 1/2"
Halex # 90661
Zinc die cast. Indoors or outdoors. Use to secure SE/SEU cable to a metal enclosure. Use to connect UF cable to a waterproof box with a threaded hub. For flat style cable: 2 insulating conductors, 1 bare. Minimize or Learn More more... |
Watertight Connector, 1 1/4"
Halex # 8212
Zinc die cast. Indoors or outdoors. Use to secure SE/SEU cable to a metal enclosure. Use to connect UF cable to a waterproof box with a threaded hub. For flat style cable: 2 insulating conductors, 1 bare. Minimize or Learn More more... |
Watertight Connector, 2"
Halex # 10420
Zinc die cast. Indoors or outdoors. Use to secure SE/SEU cable to a metal enclosure. Use to connect UF cable to a waterproof box with a threaded hub. For flat style cable: 2 insulating conductors, 1 bare. Minimize or Learn More more... |
Watertight Connector, 2"
Halex # 10220
Zinc die cast. Indoors or outdoors. Use to secure SE/SEU cable to a metal enclosure. Use to connect UF cable to a waterproof box with a threaded hub. For flat style cable: 2 insulating conductors, 1 bare. Minimize or Learn More more... |
Zinc Die Cast Connect, 1/2"
Halex # 11005B
Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to a steel outlet box or other metal enclosure. 3/8" size fits 1/2" K.O. Minimize or Learn More more... |
Zinc Die Cast Connect, 3/4"
Halex # 11007B
Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield or BX) to a steel outlet box or other metal enclosure. 3/8" size fits 1/2" K.O. Minimize or Learn More more... |
Clamp Combination Connector, 3/8"
Halex # 05703B
Indoors. In a dry location, use to connect flexible metallic conduit, AC, MC, or NM cable to steel outlet box or other enclosure. Miscellaneous: 3/8" size fits 1/2" knockout. Suitable For: #14/2 thru 12/3 with ground NM sheathed cable, #14-2 wire steel armored cable, 3/8" steel flexible metal conduit, aluminum cont. corrugated metal clad cable 0.365-0.519" diameter aluminum smooth sheath metal clad cable 0.345-0.525" diameter aluminum interlocked metal clad cable 0.455-0575" diameter rect. aluminum cont. corrugated metal clad cable 0.277" x 0.375", steel interlocked metal clad cable 0.435-0.547" diameter. Minimize or Learn More more... |
Set Screw EMT Offset Connector, 1/2"
Halex # 03705B
Indoors Only. Use to connect Emt conduit to a metal outlet box or enclosure where an offset is desired. Features: Concrete-Tight. Minimize or Learn More more... |
UF Cable Watertight Connector, 1/2"
Halex # 06605B
Indoors or Outdoors. Fits UF Cable Only: #14/2, #12/2. Use to secure SE/SEU cable to a metal enclosure. Use to secure UF cable to a waterproof box with threaded hub. Purpose: For SE/SEU Flat Style Cable and UF cable; two insulating conductors, one bare. Minimize or Learn More more... |
Clamp Combo Connector, 3/8"
Halex # 05703B
Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield, BX, NM or Metal Clad) to a steel outlet box or other metal enclosure. 3/8" size fits 1/2" K.O. U. L. Approved. Minimize or Learn More more... |
EMT Compression Connector, 1/2"
Halex # 90291
Zinc die cast. Rain-tight and concrete-tight. Indoor or outdoor applications. Use to connect E.M.T. conduit to a metal outlet box or enclosure where a 90 degree bend is required and a pipe bending tool is not used. Minimize or Learn More more... |
EMT Compression Connector, 2"
Halex # 02120
Zinc die cast. Use to connect E.M.T. conduit to steel outlet box, load center or other metal enclosure. U.L. Approved. Minimize or Learn More more... |
Flex Box Cable Connector, 3/8"
Halex # 90580
Zinc die cast. In a dry location, use to connect BX cable to a steel outlet box or other metal enclosure. 3/8" size fits 1/2" K.O. U.L. Approved. Minimize or Learn More more... |
Flex Box Clamp Connector, 3/8"
Halex # 90570
Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield, BX, NM or Metal Clad) to a steel outlet box or other metal enclosure. 3/8" size fits 1/2" K.O. U. L. Approved. Minimize or Learn More more... |
Flex Box Duplex Connector, 3/8"
Halex # 15803B
Zinc die cast. In a dry location, use to connect two pieces of flexible armored cable (Greenfield or BX) to a steel outlet box or other metal enclosure, when using only one knock-out opening. U.L. Approved. Minimize or Learn More more... |
Liquid Tight Connector, 1"
Halex # 16210B
Multi-piece. Zinc die cast. 3/8" size fits 1/2" K.O. Use to connect liquid-tight conduit to a steel outlet box or other metal enclosure or hub. U.L. Listed. Minimize or Learn More more... |