Clamp Combination Connector, 3/8"
Halex # 05703B
Indoors. In a dry location, use to connect flexible metallic conduit, AC, MC, or NM cable to steel outlet box or other enclosure. Miscellaneous: 3/8" size fits 1/2" knockout. Suitable For: #14/2 thru 12/3 with ground NM sheathed cable, #14-2 wire steel armored cable, 3/8" steel flexible metal conduit, aluminum cont. corrugated metal clad cable 0.365-0.519" diameter aluminum smooth sheath metal clad cable 0.345-0.525" diameter aluminum interlocked metal clad cable 0.455-0575" diameter rect. aluminum cont. corrugated metal clad cable 0.277" x 0.375", steel interlocked metal clad cable 0.435-0.547" diameter. Minimize or Learn More more... |
Clamp Connector For Non-Metallic Cable
Halex # 05107B
Indoors Only. Fits NM Cable: #14/2 Round, #12/3-8/3 AWG or Flex cord .460 to .720 inches diameter 3/8" (1/2ko). Type: Twin Screw. In a dry location, use to connect nonmetallic sheathed cable to a steel outlet box or other metal enclosure. Miscellaneous: 1/2" knockout. Minimize or Learn More more... |
Clamp Connector, 3/8"
Halex # 05103B
Zinc die cast. In a dry location, use to connect non-metallic sheathed cable to a steel outlet box, load center or other metal enclosure. 3/8" size fits 1/2" knock out Nos. 05103, 90510, 20510, 20517, and 40510 - Fits NM cable #14/2, #12/2. Nos. 05107, 90512, and 40512 - Fits NM cable #12-3, #10-3, #8-2; SE cable #10-3, #6-2, #6-3, #4-2, #2-2. Nos. 05110, 90513, and 40513 - Fits NM cable #12-3, #12-4, #10-3, #10-4, #8-3, #8-2, #6-2, #4-2; SE cable #6-3, #4-3, #4-0, #2-2. Nos. 05112, 90514, and 40514 - Fits NM cable #8-3, #6-3, #4-3, #2-3; SE cable #10-2, #8-2, #6-2, #4-2. Nos. 05115, and 90515 - Fits NM cable. 0.800" diameter - 1.350" diameter; SE cable #3-3, #3-2, #3-1. Nos. 05120 Fits NM cable. 0.800" diameter - 1.350" diameter; SE cable #3-4/0. Minimize or Learn More more... |
EMT 90° Connector, 1/2"
Halex # 11005B
Indoors Only. In a dry location, use to connect flexible metal conduit, aluminum and steel AC and MC cable to a steel outlet box or other metal enclosure. Miscellaneous: 3/8" size fits 1/2" knockout. Suitable For: 3/8" - 3/4" steel and aluminum armored cable, steel and aluminum interlocked metal clad cable, flexible cord, and flexible metal conduit. 1" - 4" flexible metal conduit. Minimize or Learn More more... |
EMT Conduit Nipple, 1/2"
Halex # 07005B
Indoors or Outdoors. Use with a rigid coupling to terminate threaded conduit to a knockout box or enclosure, where space within the box is limited. Used with a locknut to provide a short raceway between boxes or enclosures. Minimize or Learn More more... |
EMT Screw Connector, 3/4"
Halex # 12107B
Indoors Only. Use to connect EMT conduit to steel outlet box, load center, or other metal enclosure. Features: Concrete-Tight 1/2"-3/4", Concrete-Tight when taped 1"-4". Minimize or Learn More more... |
EMT Set Screw Connector, 1/2"
Halex # 12105B
Indoors Only. Use to connect EMT conduit to steel outlet box, load center, or other metal enclosure. Features: Concrete-Tight 1/2"-3/4", Concrete-Tight when taped 1"-4". Minimize or Learn More more... |
Set Screw EMT Offset Connector, 1/2"
Halex # 03705B
Indoors Only. Use to connect Emt conduit to a metal outlet box or enclosure where an offset is desired. Features: Concrete-Tight. Minimize or Learn More more... |
UF Cable Watertight Connector, 1/2"
Halex # 06605B
Indoors or Outdoors. Fits UF Cable Only: #14/2, #12/2. Use to secure SE/SEU cable to a metal enclosure. Use to secure UF cable to a waterproof box with threaded hub. Purpose: For SE/SEU Flat Style Cable and UF cable; two insulating conductors, one bare. Minimize or Learn More more... |
UF Cable Watertight Connector, 3/4"
Halex # 06607B
Indoors or Outdoors. Fits UF Cable Only: #12/2, #12/3. Use to secure SE/SEU cable to a metal enclosure. Use to connect UF cable to a waterproof box with threaded hub. Purpose: for UF cable; two insulating conductors, one bare. Minimize or Learn More more... |
Box Spacer, 3/4"
Halex # 16407B
Zinc die cast. Use as a raceway between two steel outlet boxes or other metal enclosures. U.L. Listed. Minimize or Learn More more... |
Clamp Combo Connector, 3/8"
Halex # 05703B
Zinc die cast. In a dry location, use to connect flexible metallic conduit (Greenfield, BX, NM or Metal Clad) to a steel outlet box or other metal enclosure. 3/8" size fits 1/2" K.O. U. L. Approved. Minimize or Learn More more... |
Clamp Connector, 1"
Halex # 90513
Zinc die cast. In a dry location, use to connect non-metallic sheathed cable to a steel outlet box, load center or other metal enclosure. 3/8" size fits 1/2" knock out Nos. 05103, 90510, 20510, 20517, and 40510 - Fits NM cable #14/2, #12/2. Nos. 05107, 90512, and 40512 - Fits NM cable #12-3, #10-3, #8-2; SE cable #10-3, #6-2, #6-3, #4-2, #2-2. Nos. 05110, 90513, and 40513 - Fits NM cable #12-3, #12-4, #10-3, #10-4, #8-3, #8-2, #6-2, #4-2; SE cable #6-3, #4-3, #4-0, #2-2. Nos. 05112, 90514, and 40514 - Fits NM cable #8-3, #6-3, #4-3, #2-3; SE cable #10-2, #8-2, #6-2, #4-2. Nos. 05115, and 90515 - Fits NM cable. 0.800" diameter - 1.350" diameter; SE cable #3-3, #3-2, #3-1. Nos. 05120 Fits NM cable. 0.800" diameter - 1.350" diameter; SE cable#3-4/0. Minimize or Learn More more... |
Conduit Chase Nipple, 1/2"
Halex # 07012
Use to terminate to a knockout box or enclosure, where space within the box is limited. Used with a locknut to provide a short raceway between boxes or enclosures. CSA, U.L. Approved. Minimize or Learn More more... |
Conduit Chase Nipple, 3/4"
Halex # 90702
Zinc die cast. Indoor or outdoor applications. Use to terminate threaded conduit to a knockout box or enclosure, where space within the box is limited. Used with a locknut to provide a short raceway between boxes or enclosures. U.L. Approved. Minimize or Learn More more... |
Conduit Nipple, 2 1/2"
Halex # 07025B
Zinc die cast. Indoor or outdoor applications. Use to terminate threaded conduit to a knockout box or enclosure, where space within the box is limited. Used with a locknut to provide a short raceway between boxes or enclosures. U.L. Approved. Minimize or Learn More more... |
Conduit Nipple, 2"
Halex # 07020
Zinc die cast. Indoor or outdoor applications. Use to terminate threaded conduit to a knockout box or enclosure, where space within the box is limited. Used with a locknut to provide a short raceway between boxes or enclosures. U.L. Approved. Minimize or Learn More more... |
EMT Compression Connector, 1 1/4"
Halex # 02112
Zinc die cast. Use to connect E.M.T. conduit to steel outlet box, load center or other metal enclosure. U.L. Approved. Minimize or Learn More more... |
EMT Compression Connector, 1"
Halex # 02110
Zinc die cast. Use to connect E.M.T. conduit to steel outlet box, load center or other metal enclosure. U.L. Approved. Minimize or Learn More more... |
EMT Compression Connector, 1-1/2"
Halex # 02115
Zinc die cast. Use to connect E.M.T. conduit to steel outlet box, load center or other metal enclosure. U.L. Approved. Minimize or Learn More more... |
EMT Compression Connector, 1/2"
Halex # 90291
Zinc die cast. Rain-tight and concrete-tight. Indoor or outdoor applications. Use to connect E.M.T. conduit to a metal outlet box or enclosure where a 90 degree bend is required and a pipe bending tool is not used. Minimize or Learn More more... |