Circuit Breaker, 60 Amp
Siemens Energy # MP260
Two pole circuit breaker. |
2 Pole 60 Amp Circuit Breaker
Cutler-Hammer # CH260
3/4" per pole, 120/240 Volts ac. 10,000 AIC. Quick make, quick break switch, inverse time element tripping operation and trip free handle. Thermal-magnetic trip curve. #14 - 8 wire range 15 to 30 amp, #14 - 2 wire range 40 to 70 amp, #10 - 1/0 wire range100 amp. U.L. Listed, HACR rated, meets NEMA standards and Federal Specifications, CSA certified. Minimize or Learn More more... |
2" 60 Amp Interchangeable Breaker
GE Electric # THQL2160
1" module, 120/240 Volts ac; 10,000 AIC. Copper-to-copper connections, calibrated for optimum trip performance, heat resistant thermoset cases and covers, cemented calibration screw. May be used, when marked to accept, with American Switch, Arrow Hart, Bryant, General Switch, GTE, Sylvania, most ITE, Murray, Westinghouse Type BR, Challenger, Crouse-Hinds. 15 to 30 amp 14 - 8 Cu or 12 - 8 Al AWG wire, 35 to 60 amp 8 - 3 Cu or 8 - 2 Al AWG wire, 70 to 100 amp 6-1/0 Cu or 4 - 1/0 Al AWG wire. U.L. Listed, HACR rated. Minimize or Learn More more... |
60 Amp 2 Pole Circuit Breaker
Siemens Energy # Q260
Molded case with non-interchangeable trip. 120/240 Volts ac; 10,000 AIR. Will replace American Switch, Westinghouse Type BR, Bryant, Challenger, Sylvania, Crouse-Hinds, Murray, Frank Adams, General Electric (Full size only), General Switch, I-T-E, Gould,Montgomery Ward and Sears. U.L. Listed. HACR rated. Minimize or Learn More more... |
60 Amp Circuit Breaker
Connecticut Electric # CH260
Replacement For Cutler-Hammer 120/240 volts AC, 10,000 AIC. Two 3/4" space required. Minimize or Learn More more... |
60 Amp Circuit Breaker
Connecticut Electric # UBIZ0260
Replacement for Zinsco. 120/240 Volt. |
60Amp 2 Pole Interchangeable Breaker
Connecticut Electric # ICBQ260
Interchangeable group will fit most General Electric, General Switch, ITE, Murray, American Switch, Westinghouse Type BR and Bryant. ITE/SIEMENS 120/240 Volt. Minimize or Learn More more... |
60Amp 2 Pole Thick Circuit Breaker
Connecticut Electric # UBI-F260N
Replacement for Federal Pacific Load Centers. 120/240 Volt. Minimize or Learn More more... |
Plug-On Common Trip Circuit Breaker, 60 Amps
Cutler-Hammer # BR260
Switching duty rating, 2" per breaker, 120/240 V. 10,000 AIR. Thermal magnetic 40 degrees Celsius. Interchangeable, will replace: New General Electric, Murray, ITE (except Pushmatic), Bryant, General, American, Crouse-Hinds, Sylvania, Challenger and Westinghouse Type BR. Minimize or Learn More more... |
Plug-On Double Pole Circuit Breaker, 60 Amps
Your One Source # HOM260CP
Format 1". Thermal/magnetic tripping mechanism. 120/240 V; 10,000 AIR. U.L. Listed as HACR type for use with air conditioning, heating and refrigeration equipment having motor group combinations and marked for use with HACR type circuit breakers. Minimize or Learn More more... |
Two Pole Square D Compatible Circuit Breaker, 60 Amp
Connecticut Electric # D260
120/240 volt AC, 10,000 AIC. Two Pole, plug in, requires two 3/4" spaces. Suitable replacement for QO Square D breakers. HACR/SWD rated. Minimize or Learn More more... |
Two Pole Visi-Trip Circuit Breaker, 60 Amp
Your One Source # QO260CP
Full size 3/4" breakers, 120/240 V; 10,000 AIR. U.L. Listed as HACR type for use with equipment having motor group combinations and marked for HACR breakers. Minimize or Learn More more... |
Zinsco Full Breaker, 60 Amp
Connecticut Electric # UBIZ260
|
Circuit Breaker, 2 Pole 60 Amp
Cutler-Hammer # CHQ260
120/240 volt AC, 10,000 AIC, wire size range(1) #14-8, (2) #14-10. UL listed, meets UL 489. Replacement for Square D type QO breakers. Requires two 3/4-inch (19.1 mm) spaces. Minimize or Learn More more... |