Two Pole Circuit Breaker, 50 Amp
Siemens Energy # MP250
Two pole circuit breaker, 50 amp. Use only with listed enclosure. Minimize or Learn More more... |
Two Pole Circuit Breaker, 50 Amp
Hardware By Barnett # 606250
Two pole circuit breaker. |
Two Pole Circuit Breaker, 50 Amp
Siemens Energy # QO250CP
Two pole circuit breaker. |
1/2 50 Amp 2 Pole Circuit Breaker
GE Electric # THQP250
1/2" module, 120/240 Volts ac; 10,000 AIC. Copper-to-copper connections, calibrated for optimum trip performance, heat resistant thermoset cases and covers, cemented calibration screw. Nearly identical to Type THQL with the same design and performance, yet only taking up 1/2 the space. U.L. Listeed, HACR rated. 15 to 25 amp 14 - 8 Cu or 12 - 8 Al AWG wire, 30 to 50 amp 8 - 4 Cu or 8 - 2 Al AWG wire. 3-9/32"H x 1/2"W x 2-3/8"D overall. Minimize or Learn More more... |
2" 50 Amp Interchangeable Breaker
GE Electric # THQL2150
1" module, 120/240 Volts ac; 10,000 AIC. Copper-to-copper connections, calibrated for optimum trip performance, heat resistant thermoset cases and covers, cemented calibration screw. May be used, when marked to accept, with American Switch, Arrow Hart, Bryant, General Switch, GTE, Sylvania, most ITE, Murray, Westinghouse Type BR, Challenger, Crouse-Hinds. 15 to 30 amp 14 - 8 Cu or 12 - 8 Al AWG wire, 35 to 60 amp 8 - 3 Cu or 8 - 2 Al AWG wire, 70 to 100 amp 6-1/0 Cu or 4 - 1/0 Al AWG wire. U.L. Listed, HACR rated. Minimize or Learn More more... |
50 Amp 2 Pole Circuit Breaker
Connecticut Electric # THQP250
For G.E. Old Style Load Centers. 120/240 Volt. Minimize or Learn More more... |
50 Amp 2 Pole Circuit Breaker
Siemens Energy # Q250
Molded case with non-interchangeable trip. 120/240 Volts ac; 10,000 AIR. Will replace American Switch, Westinghouse Type BR, Bryant, Challenger, Sylvania, Crouse-Hinds, Murray, Frank Adams, General Electric (Full size only), General Switch, I-T-E, Gould,Montgomery Ward and Sears. U.L. Listed. HACR rated. Minimize or Learn More more... |
50 Amp 2 Pole Interchangeable Breaker
Connecticut Electric # ICBQ250
Interchangeable group will fit most General Electric, General Switch, ITE, Murray, American Switch, Westinghouse Type BR and Bryant. ITE/SIEMENS 120/240 Volt. Minimize or Learn More more... |
50 Amp 2 Pole Thick Circuit Breaker
Connecticut Electric # UBI-F250N
Replacement for Federal Pacific Load Centers. 120/240 Volt. Minimize or Learn More more... |
50 Amp 2 Pole Thin Circuit Breaker
Connecticut Electric # UBI-F0250N
For Federal Pacific Load Centers. 120/240 Volt. Minimize or Learn More more... |
50 Amp Circuit Breaker
Connecticut Electric # CH250
Replacement For Cutler-Hammer 120/240 volts AC, 10,000 AIC. Two 3/4" space required. Minimize or Learn More more... |
50 Amp Circuit Breaker
Connecticut Electric # UBIZ0250
Replacement for Zinsco. 120/240 Volt. |
Plug-On Common Trip Circuit Breaker, 50 Amps
Cutler-Hammer # BR250
Switching duty rating, 2" per breaker, 120/240 V. 10,000 AIR. Thermal magnetic 40 degrees Celsius. Interchangeable, will replace: New General Electric, Murray, ITE (except Pushmatic), Bryant, General, American, Crouse-Hinds, Sylvania, Challenger and Westinghouse Type BR. Minimize or Learn More more... |
Plug-On Double Pole Circuit Breaker, 50 Amps
Your One Source # HOM250CP
Format 1". Thermal/magnetic tripping mechanism. 120/240 V; 10,000 AIR. U.L. Listed as HACR type for use with air conditioning, heating and refrigeration equipment having motor group combinations and marked for use with HACR type circuit breakers. Minimize or Learn More more... |
Square D Compatible Circuit Breaker, 50 Amp
Connecticut Electric # D250
120/240 volt AC, 10,000 AIC. Two Pole, plug in, requires two 3/4" spaces. Suitable replacement for QO Square D breakers. HACR/SWD rated. Minimize or Learn More more... |
Two Pole Circuit Breaker, 50 Amp
Connecticut Electric # UBITB-A250
Requires one 1" space. HACR rated. 120/240 volts AC. 10,000 AIC. Also known as Challenger "A" Series. Minimize or Learn More more... |
Two Pole Circuit Breaker, 50 Amp
Cutler-Hammer # CL250
120/240 volt AC, 10,000 AIC, wire size range #14-4. Type CL replacement breakers, classified as direct replacements by Underwriters Laboratories for Square D HOMELINE, General Electric, Crouse-Hinds, Thomas & Betts, Murray and ITE_/Siemens loadcenters Minimize or Learn More more... |
Two Pole Circuit Breaker, 50 Amp
Cutler-Hammer # CHQ250
120/240 volt AC, 10,000 AIC, wire size range(1) #14-8, (2) #14-10. UL listed, meets UL 489. Replacement for Square D type QO breakers. Requires two 3/4-inch (19.1 mm) spaces. Minimize or Learn More more... |
Two Pole Circuit Breaker, 50 amp
Siemens Energy # MQ250
UL classified for over 90 Square D load centers. Circuit breakers are switches that automatically shut off the flow of electricity to protect the wiring in your home from damage due to excessive current flowing in the wires. AMPS 30 POLES 2 WIRE SIZE AWG 10-3. Minimize or Learn More more... |