1" 40 Amp Interchangeable Breaker
GE Electric # THQL1140
1" module, 120/240 Volts ac; 10,000 AIC. Copper-to-copper connections, calibrated for optimum trip performance, heat resistant thermoset cases and covers, cemented calibration screw. May be used, when marked to accept, with American Switch, Arrow Hart, Bryant, General Switch, GTE, Sylvania, most ITE, Murray, Westinghouse Type BR, Challenger, Crouse-Hinds. 15 to 30 amp 14 - 8 Cu or 12 - 8 Al AWG wire, 35 to 60 amp 8 - 3 Cu or 8 - 2 Al AWG wire. U.L. Listed, HACR rated. Minimize or Learn More more... |
1/2 40 Amp 2Pole Circuit Breaker
GE Electric # THQP140
1/2" module, 120/240 Volts ac; 10,000 AIC. Copper-to-copper connections, calibrated for optimum trip performance, heat resistant thermoset cases and covers, cemented calibration screw. Nearly identical to Type THQL with the same design and performance, yet only taking up 1/2 the space. U.L. Listeed, HACR rated. 15 and 20 amp SWD, switching duty rated, suitable for 120 Volts ac fluorescent lighting loads. 15 to 25 amp #14 - 8 Cu or #12 - 8 Al AWG wire, 30 to 50 amp #8 - 4 Cu or #8 - 2 Al AWG wire. 3-9/32"H x 1/2"W x 2-3/8"D overall. Minimize or Learn More more... |
40 Amp 1 Pole Plug On Circuit Breaker
Your One Source # QO140CP
Full size 3/4" breakers, 120/240 Volts ac; 10,000 AIR. U.L. Listed as HACR type for use with equipment having motor group combinations and marked for HACR breakers. 15 and 20 amp breakers are also U.L. Listed for switching 120 Volt ac fluorescent lightingloads. Minimize or Learn More more... |
40 Amp Plug On Circuit Breaker
Cutler-Hammer # BR140
Switching duty rating, 1" per pole, 120/240 volts, AC, 10,000 AIC interrupting rating. Thermal magnetic 40 degrees C. Interchangeable will replace: New General Electric, Murray, ITE (except Pushmatic), Bryant, General, American, Crouse-Hinds, Sylvania,Challenger and Westinghouse Type BR. Minimize or Learn More more... |
40 Amp Single Pole Circuit Breaker
Your One Source # HOM140CP
Format 1". Thermal/magnetic tripping mechanism. 120/240 Volt ac; 10,000 AIC. U.L. Listed as HACR type for use with air conditioning, heating and refrigeration equipment having motor group combinations and marked for use with HACR type circuit breakers. 15 and 20 amp switching duty rated for switching 120 Volt fluorescent lighting loads. Minimize or Learn More more... |
Single Pole Circuit Breaker, 40A
Cutler-Hammer # CH140
Quick make, quick break switch, inverse time element tripping operation and trip free handle. Thermal-magnetic trip curve. UL Listed, HACR rated, meets NEMA standards and Federal Specifications, CSA certified. 120 volt AC. 10,000 AIR. Minimize or Learn More more... |
Two Pole Circuit Breaker, 40 Amp
Your One Source # QO240CP