Two Pole Circuit Breaker, 20 Amp
Siemens Energy # MP2020
Two pole circuit breaker in 20 Amps. |
Two Pole Circuit Breaker, 20 Amp
Siemens Energy # MP220
Two pole circuit breaker. |
1/2 20 Amp 2 Pole Circuit Breaker
GE Electric # THQP220
1/2" module, 120/240 Volts ac; 10,000 AIC. Copper-to-copper connections, calibrated for optimum trip performance, heat resistant thermoset cases and covers, cemented calibration screw. Nearly identical to Type THQL with the same design and performance, yet only taking up 1/2 the space. U.L. Listeed, HACR rated. 15 to 25 amp 14 - 8 Cu or 12 - 8 Al AWG wire, 30 to 50 amp 8 - 4 Cu or 8 - 2 Al AWG wire. 3-9/32"H x 1/2"W x 2-3/8"D overall. Minimize or Learn More more... |
2 Pole 20 Amp Circuit Breaker
Cutler-Hammer # CH220
3/4" per pole, 120/240 Volts ac. 10,000 AIC. Quick make, quick break switch, inverse time element tripping operation and trip free handle. Thermal-magnetic trip curve. #14 - 8 wire range 15 to 30 amp, #14 - 2 wire range 40 to 70 amp, #10 - 1/0 wire range100 amp. U.L. Listed, HACR rated, meets NEMA standards and Federal Specifications, CSA certified. Minimize or Learn More more... |
2' 20 Amp Interchangeable Breaker
GE Electric # THQL2120
1" module, 120/240 Volts ac; 10,000 AIC. Copper-to-copper connections, calibrated for optimum trip performance, heat resistant thermoset cases and covers, cemented calibration screw. May be used, when marked to accept, with American Switch, Arrow Hart, Bryant, General Switch, GTE, Sylvania, most ITE, Murray, Westinghouse Type BR, Challenger, Crouse-Hinds. 15 to 30 amp 14 - 8 Cu or 12 - 8 Al AWG wire, 35 to 60 amp 8 - 3 Cu or 8 - 2 Al AWG wire, 70 to 100 amp 6-1/0 Cu or 4 - 1/0 Al AWG wire. U.L. Listed, HACR rated. Minimize or Learn More more... |
20 Amp 2 Pole Circuit Breaker
Siemens Energy # Q220
Molded case with non-interchangeable trip. 120/240 Volts ac; 10,000 AIR. Will replace American Switch, Westinghouse Type BR, Bryant, Challenger, Sylvania, Crouse-Hinds, Murray, Frank Adams, General Electric (Full size only), General Switch, I-T-E, Gould,Montgomery Ward and Sears. U.L. Listed. HACR rated. Minimize or Learn More more... |
20 Amp 2 Pole Circuit Breaker
Connecticut Electric # THQP220
For G.E. Old Style Load Centers. 120/240 Volt. Minimize or Learn More more... |
20 Amp 2 Pole Circuit Breaker
Connecticut Electric # UBIP220
For ITE Pushmatic Load Centers. 120/240 Volt. Minimize or Learn More more... |
20 Amp 2 Pole Interchangeable Breaker
Connecticut Electric # ICBQ220
Interchangeable group will fit most General Electric, General Switch, ITE, Murray, American Switch, Westinghouse Type BR and Bryant. ITE/SIEMENS 120/240 Volt. Minimize or Learn More more... |
20 Amp 2 Pole Thin Circuit Breaker
Connecticut Electric # UBI-F0220N
For Federal Pacific Load Centers. 120/240 Volt. Minimize or Learn More more... |
20 Amp Circuit Breaker
Connecticut Electric # CH220
Replacement For Cutler-Hammer 120/240 volts AC, 10,000 AIC. Two 3/4" space required. Minimize or Learn More more... |
20 Amp Double Thick Pole Breaker
Connecticut Electric # UBI-F220N
Replacement for Federal Pacific Load Centers. 120/240 Volt. Minimize or Learn More more... |
20 Amps Circuit Breaker
Connecticut Electric # UBIZ0220
Replacement for Zinsco. 120/240 Volt. |
20/ 20 Amp Circuit Breakers
Cutler-Hammer # BD2020
Switching duty rating, 1/2" per pole Duplex type breaker requires 1" per breaker. 120/240 volts, AC.. 10,000 AIC interrupting rating. Thermal magnetic 40 degrees C breakers have rejection tab feature, allows only 42 circuits in the panel in compliance with NEC article 384-15. Interchangeable will replace: New General Electric, Murray, ITE (except Pushmatic), Bryant, General, American, Crouse-Hinds, Sylvania, Challenger and Westinghouse Type BR. Minimize or Learn More more... |
Double Pole Circuit Breaker, 20 Amp
Cutler-Hammer # CHQ220
120/240 volt AC, 10,000 AIC, wire size range(1) #14-8, (2) #14-10. UL listed, meets UL 489. Replacement for Square D type QO breakers. Requires two 3/4-inch (19.1 mm) spaces. Minimize or Learn More more... |
Duplex Type BR Circuit Breaker, 20 Amps
Cutler-Hammer # BR2020
Non-circuit limiting, less rejection tabs. One space required, 120/240 Volts AC, 10,000 AIC. Minimize or Learn More more... |
Plug-0n Double Pole Circuit Breaker, 20 Amp
Your One Source # HOM220CP
Format 1". Thermal/magnetic tripping mechanism. 120/240 V; 10,000 AIR. U.L. Listed as HACR type for use with air conditioning, heating and refrigeration equipment having motor group combinations and marked for use with HACR type circuit breakers. Minimize or Learn More more... |
Plug-On Common Trip Circuit Breaker, 20 Amps
Cutler-Hammer # BR220
Switching duty rating, 2" per breaker, 120/240 V. 10,000 AIR. Thermal magnetic 40 degrees Celsius. Interchangeable, will replace: New General Electric, Murray, ITE (except Pushmatic), Bryant, General, American, Crouse-Hinds, Sylvania, Challenger and Westinghouse Type BR. Minimize or Learn More more... |
Square D Compatible Circuit Breaker, 20 Amp
Connecticut Electric # D220
120/240 volt AC, 10,000 AIC. Two Pole, plug in, requires two 3/4" spaces. Suitable replacement for QO Square D breakers. HACR/SWD rated. Minimize or Learn More more... |
Thin Twin Circuit Breaker, 20 Amp
Connecticut Electric # UBIZ2020
|
Two Pole Circuit Breaker, 20 Amp
Connecticut Electric # UBITB-A220
Requires one 1" space. HACR rated. 120/240 volts AC. 10,000 AIC. Also known as Challenger "A" Series. Minimize or Learn More more... |