Circuit Breaker, 15 Amp
Your One Source # QO115CP
Full size 3/4" breakers, 120/240 Volts ac; 10,000 AIR. U.L. Listed as HACR type for use with equipment having motor group combinations and marked for HACR breakers. 15 and 20 amp breakers are also U.L. Listed for switching 120 Volt ac fluorescent lighting loads. Minimize or Learn More more... |
One Pole Circuit Breaker, 15 Amp
Siemens Energy # MP115
One pole circuit breaker |
Single Pole Circuit Breaker, 15 Amp
Hardware By Barnett # CH115
Single pole circuit breaker |
1" 15 Amp Interchangeable Breaker
GB Electrical # THQL1115
1" module, 120/240 Volts ac; 10,000 AIC. Copper-to-copper connections, calibrated for optimum trip performance, heat resistant thermoset cases and covers, cemented calibration screw. May be used, when marked to accept, with American Switch, Arrow Hart, Bryant, General Switch, GTE, Sylvania, most ITE, Murray, Westinghouse Type BR, Challenger, Crouse-Hinds. 15 to 30 amp 14 - 8 Cu or 12 - 8 Al AWG wire, 35 to 60 amp 8 - 3 Cu or 8 - 2 Al AWG wire. U.L. Listed, HACR rated. Minimize or Learn More more... |
1/2 15 Amp 2 Pole Circuit Breaker
GB Electrical # THQP115
1/2" module, 120/240 Volts ac; 10,000 AIC. Copper-to-copper connections, calibrated for optimum trip performance, heat resistant thermoset cases and covers, cemented calibration screw. Nearly identical to Type THQL with the same design and performance, yet only taking up 1/2 the space. U.L. Listeed, HACR rated. 15 and 20 amp SWD, switching duty rated, suitable for 120 Volts ac fluorescent lighting loads. 15 to 25 amp #14 - 8 Cu or #12 - 8 Al AWG wire, 30 to 50 amp #8 - 4 Cu or #8 - 2 Al AWG wire. 3-9/32"H x 1/2"W x 2-3/8"D overall. Minimize or Learn More more... |
15 Amp 1 Pole Circuit Breaker
Connecticut Electric # THQP115
For G.E. Old Style Load Centers. 120/240 Volt. Minimize or Learn More more... |
15 Amp 1 Pole Thick Circuit Breaker
Connecticut Electric # UBI-F15N
Replacement for Federal Pacific Load Centers. 120/240 Volt. Minimize or Learn More more... |
15 Amp 1 Pole Thin Circuit Breaker
Connecticut Electric # UBI-F015N
For Federal Pacific Load Centers. 120/240 Volt. Minimize or Learn More more... |
15 Amp 1Pole Interchangeable Breaker
Connecticut Electric # ICBQ115
Interchangeable group will fit most General Electric, General Switch, ITE, Murray, American Switch, Westinghouse Type BR and Bryant. ITE/SIEMENS 120/240 Volt. Minimize or Learn More more... |
15 Amp Circuit Breaker
Connecticut Electric # CH115
Replacement For Cutler-Hammer 120 volts AC, 10,000 AIC. One 3/4" space required. Minimize or Learn More more... |
15 Amp Dual Circuit Breaker
Siemens Energy # Q1515
Complete, unenclosed, molded case breaker with non-interchangeable trip. 120/240 Volts ac; 10,000 AIR. Takes the place of 2 single pole breakers in 1" of space. Will replace American Switch, Westinghouse Type BR, Bryant, Challenger, Sylvania, Crouse-Hinds, Murray, Frank Adams, General Electric (full size only), General Switch, I-T-E, Gould, Montgomery Ward and Sears. HACR rated. Minimize or Learn More more... |
15 Amp Duplex Interchangable Breaker
Connecticut Electric # ICBQ1515
Interchangeable group will fit most General Electric, General Switch, ITE, Murray, American Switch, Westinghouse Type BR and Bryant. Minimize or Learn More more... |
15 Amp Single Pole Circuit Breaker
Siemens Energy # Q115
Non-interchangeable trip. 120 Volts ac; 10,000 AIR. Will replace American Switch, Westinghouse Type BR, Bryant, Challenger, Sylvania, Crouse-Hinds, Murray, Frank Adams, General Electric (Full size only), General Switch, I-TE, Gould, Montgomery Ward and Sears. U.L. Listed, HACR rated. 15 and 20 amp U.L. Listed for frequent switching applications, 120 Volt ac fluorescent lighting. Minimize or Learn More more... |
15/ 15A Plug On Circuit Breaker
Your One Source # QOT1515CP
QO Tandem for Load Centers with Pan Rail Slots Only. Circuit limiting. U.L. Listed. Minimize or Learn More more... |
Arc Fault Breaker, Qo 15 Amp
Your One Source # QO115AFIC
120 volts, 10,000 AIR. Provides ARC fault, overload and short circuit protection. Protects against damaged wires, worn electrical insulation, loose electrical connections, wires or cords in contact with vibrating metal, overheated or stressed electricalcords and wires and misapplied or damaged electrical applications. Required for bedroom receptacles effective January 1, 2002. UL Listed. Minimize or Learn More more... |
ARC Fault Combination Circuit Breaker, 15 Amp
Siemens Energy # Q115AFC
Plug-in, combination type AFCI circuit breaker, complies with the requirements for both branch/feeder and outlet circuit AFCIs. Required on January 1, 2008 by 2005 NEC, combination type AFCI circuit breakers must be placed on bedroom power and lighting circuits. It is intended to protect downstream branch circuit wiring and cord sets and power-supply cords. Provides ARC fault, overload and short circuit protection. UL listed. Protects against worn electrical insulation or damaged wire, misapplied or damaged plug in appliances and equipment, and loose electrical connections. 2 LEDs appear for 5 seconds each time the AFCI is turned “ON” up to 30 days after the last trip to indicate last known trip condition. One LED means arcing fault. Two LEDs means arcing fault to ground. 10kA interrupting rating. UL Listed, 120 volts AC. Wire range 14 - 8 AWG. Minimize or Learn More more... |
Circuit Breaker, 15 Amp
Cutler-Hammer # CL115
120/240 volt AC, 10,000 AIC, wire size range #14-4. Type CL replacement breakers, classified as direct replacements by Underwriters Laboratories for Square D HOMELINE, General Electric, Crouse-Hinds, Thomas & Betts, Murray and ITE/Siemens loadcenters. Requires one 1-Inch (25.4 mm) space. Minimize or Learn More more... |
GE Single Pole Circuit Breaker, 15 Amp
Connecticut Electric # THQL1115
General Electric thick series, one breaker. Requires one 1" space. HACR, 10,000 AIC and 120/240 VAC. Minimize or Learn More more... |
Homeline 15 Amp Arc Fault Breaker
Your One Source # HOM115AFIC
|
Homeline Single Pole 15 Amp (10Pc)
Your One Source # HOM115TP
Format 1". Thermal/magnetic tripping mechanism. 120/240 Volt ac; 10,000 AIC. U.L. Listed as HACR type for use with air conditioning, heating and refrigeration equipment having motor group combinations and marked for use with HACR type circuit breakers. 15 and 20 amp switching duty rated for switching 120 Volt fluorescent lighting loads. Minimize or Learn More more... |
MQ Circuit Breaker, 15 Amp Single Pole
Siemens Energy # MQ115
Square D QO compatible - 3/4" plug-in format. UL classified for use in specific Square D load centers in place of Square D QO circuit breakers. Supplied with load side connectors suitable for 60/75 degree C wire and are calibrated for 40 degree C maximumambient applications. Rated at 120/240 volt AC. HACR rated. Minimize or Learn More more... |