Two Pole Circuit Breaker, 15 Amp
Siemens Energy # MP1515
Two pole circuit breaker |
Two Pole Circuit Breaker, 15 Amp
Siemens Energy # MP215
Two pole circuit breaker. |
15 Amp Push Type Dual Circuit Breaker
Connecticut Electric # UBIP1515
For ITE Pushmatic Load Centers. 120/240 Volt. Minimize or Learn More more... |
2 Pole 15 Amp Circuit Breaker
Cutler-Hammer # CH215
3/4" per pole, 120/240 Volts ac. 10,000 AIC. Quick make, quick break switch, inverse time element tripping operation and trip free handle. Thermal-magnetic trip curve. #14 - 8 wire range 15 to 30 amp, #14 - 2 wire range 40 to 70 amp, #10 - 1/0 wire range100 amp. U.L. Listed, HACR rated, meets NEMA standards and Federal Specifications, CSA certified. Minimize or Learn More more... |
Duplex Type BR Circuit Breaker, 15 Amp
Cutler-Hammer # BR1515
Non-circuit limiting, less rejection tabs. One space required, 120/240 Volts AC, 10,000 AIC. Minimize or Learn More more... |
Homeline Tandem Circuit Breaker, 15 Amp
Your One Source # HOMT1515CP
Two single pole circuits in only one space. 120 V single pole, 120/240 V 2 pole; 10,000 AIR. U.L. Listed as HACR type for use with equipment having motor group combinations and marked for use with HACR breakers. Minimize or Learn More more... |
Plug-On Double Pole Circuit Breaker, 15 Amps
Cutler-Hammer # BR215
Switching duty rating, 2" per breaker, 120/240 V. 10,000 AIR. Thermal magnetic 40 degrees Celsius. Interchangeable, will replace: New General Electric, Murray, ITE (except Pushmatic), Bryant, General, American, Crouse-Hinds, Sylvania, Challenger and Westinghouse Type BR. Minimize or Learn More more... |
Plug-On Double Pole Circuit Breaker, 15 Amps
Your One Source # HOM215CP
Format 1". Thermal/magnetic tripping mechanism. 120/240 V; 10,000 AIR. U.L. Listed as HACR type for use with air conditioning, heating and refrigeration equipment having motor group combinations and marked for use with HACR type circuit breakers. Minimize or Learn More more... |
Plug-On Independant Trip Circuit Breaker, 15 Amp
Cutler-Hammer # BD1515
Switching duty rating, 1/2" per pole Duplex type breaker requires 1" per breaker. 120/240 V. 10,000 AIR. Thermal magnetic 40 degrees C breakers have rejection tab feature, allows only 42 circuits in the panel in compliance with NEC article 384-15. Interchangeable will replace: New General Electric, Murray, ITE (except Pushmatic), Bryant, General, American, Crouse-Hinds, Sylvania, Challenger and Westinghouse Type BR. Minimize or Learn More more... |
Thin Twin Circuit Breaker, 15 Amp
Connecticut Electric # UBIZ1515
120/240 volt AC, 10,000 AIC. Replacement for Zinsco R Series. SWD (switch duty) Rated. Tested and certified in accordance with the National Electric Code and conforms to the ANSI/UL Standard 489, 9th Edition. Minimize or Learn More more... |