GE LFL Magnetic Rapid Start Ballast
GE Electric # 89712
Magnetic ballast construction for all general fluorescent lighting. Extends lamp life in frequently switched applications. Application 1- F20T12, F15T8, F15T12, F14T12, 120V, Magnetic (546BTCP). Mounting dimensions: Bracket Length (BL) 6.4 in (163.57 mm) x Mount Length (M) 6 in (152.40 mm) x Mount Slots (MS) 1/4 in (6.35 mm). Minimize or Learn More more... |
GE LFL Multi-Volt ProLine Electronic Ballast, 120-277V
GE Electric # 97711
High performance electronic ballast for all general fluorescent applications. Instant start electronic ballast for long lamp starting cycles and low initial cost. Multi-Voltage Technology handles voltage from 120 to 277V. Light-weight, Low Profile Housing. Parallel lamp operation means system maintenance is easier to manage. Mounting dimensions: Mount Length (M) 8.8 in (225.80 mm) x Mount Width (X or F) 1.1 in (28.70 mm) x Mount Slots (MS) 0.3 in (7.92 mm). Minimize or Learn More more... |
GE Magnetic Rapid Start Ballast
GE Electric # 89711
Magnetic ballast construction for all general fluorescent lighting. Extends lamp life in frequently switched applications. Mounting dimensions: Bracket Length (BL) 3.0 in (77.01 mm) x Mount Length (M) 2 3/4 in (69.85 mm) x Mount Slots (MS) 0.2 in (5.58 mm). Minimize or Learn More more... |
GE Magnetic Standard Instant Start Ballast
GE Electric # 46965
Magnetic ballast construction for all general fluorescent lighting. Instant start ballast for long lamp starting cycles and low initial cost. Mounting dimensions: Bracket Length (BL) 11.6 in (296.92 mm) x Mount Length (M) 11 1/4 in (285.75 mm) x Mount Slots (MS) 0.3 in (7.87 mm). Minimize or Learn More more... |
GE UltraMax Electronic High Efficiency Multivolt Instant Start Ballast
GE Electric # 23954
Energy saving high efficiency instant start electronic ballast (> 90%). Multi-Voltage Technology handles voltage from 120 to 277V. Active Current Regulation regulates the output to each lamp with individual lamp inverter modules. Anti-Striation Control for better light quality, with no striations. UL Type CC Rating provides protection against arcing with F96T8 lamps only. Mounting dimensions: Mount Length (M) 8.8 in (225.80 mm) x Mount Width (X or F) 1.1 in (28.70 mm) x Mount Slots (MS) 0.3 in (7.92 mm). Minimize or Learn More more... |
Magnetic Rapid Start Ballast
GE Electric # 80819
Magnetic ballast construction for all general fluorescent lighting. Extends lamp life in frequently switched applications. Color coded ballast and package labels reduce misapplication errors (120V Yellow, 277V Red). Mounting dimensions: Bracket Length (BL) 6.5 in (166.62 mm) x Mount Length (M) 6 in (152.40 mm) x Mount Slots (MS) 0.3 in (7.87 mm). Minimize or Learn More more... |
Magnetic Rapid Start Ballast, 120V
GE Electric # 89709
Magnetic ballast construction for all general fluorescent lighting. Extends lamp life in frequently switched applications. Application 1- F40T12, F30T12, F48/25W, 120V, Magnetic Ballast (413CTCP). Mounting dimensions: Bracket Length (BL) 6.4 in (163.57 mm) x Mount Length (M) 6 in (152.40 mm) x Mount Slots (MS) 1/4 in (6.35 mm). Minimize or Learn More more... |
ProLine Electronic Multivolt Instant Start Ballast
GE Electric # 97709
High performance electronic ballast for all general fluorescent applications. Instant start electronic ballast for long lamp starting cycles and low initial cost. Multi-Voltage Technology handles voltage from 120 to 277V. Light-weight, Low Profile Housing. Parallel lamp operation means system maintenance is easier to manage. Mounting dimensions: Mount Length (M) 8.8 in (225.80 mm) x Mount Width (X or F) 1.1 in (28.70 mm) x Mount Slots (MS) 0.3 in (7.92 mm). Minimize or Learn More more... |
Ballast (1) F72 or F96 T12 Fluorescent
Advance Transformer # RSM175STPI
For operating F96T12 energy saver lamp 60 watts, F96T12 lamp 75 watts, F60T12 lamp 50 watts, F64T12 lamp 52 watts, and F72T12 lamps 57 watts. 120 volts. U.L. Listed and meets Canadian energy standard. Minimize or Learn More more... |
Ballast (1) FC8 T9 or FC12 T9
Advance Transformer # RS2232TPWI
Low power factor. For two lamps type FC8T9 or FC12T9. 22 and 32 lamp watts, 120 input volts. U.L. Listed. Minimize or Learn More more... |
Ballast (1) or (2) F32 T8 Fluores
Advance Transformer # REL2P32SCI
For operating two F25 or F32 T8 lamps, 120 volts. Minimize or Learn More more... |
Ballast (1) or (2) F96 T8 Fluorescent
Advance Transformer # REL2P59SRHTP35I
For operating one or two F96T8 lamps, 120 volts. Parallel lamp connection. Minimize or Learn More more... |
Ballast (2) F40 T12 Fluorescent
Advance Transformer # REL2S40SC35I
For operating two F40 or F30 T12 lamps, 120 volts. Minimize or Learn More more... |
Ballast (2) F72 or (2) F96 T12-120V Fluorescent, 6/8'
Connecticut Electric # I296ES
Will light two F72 (72") or two F96 (96") T12-120V lamps. Minimize or Learn More more... |
Ballast (3) or (4) F32 T8 Fluorescent
Advance Transformer # REL4P32SCI
For operating four F25 or F32 T8 lamps, 120 volts. Minimize or Learn More more... |
Ballast F40(48") T12-120V Fluorescent, 4'
Connecticut Electric # I240ES
Will light two F40(48") T12-120V lamps. |
Circline Ballast
Advance Transformer # RLCS140TPWI
Low power factor. For one lamp type FC12T9 or FC16T9. 32 or 40 lamp watts, 120 input volts. U.L. Listed, CSA approved. Minimize or Learn More more... |
Magnetic Ballast
Advance Transformer # LC1420CI
Low power factor. For one lamp type F14T8 or F14T12, F15T8 or F15T12, F18BX, F24T8, F26T8, F28T8, F20T8, F30T12. 14, 15, 18, 19, 20 lamp watts, 120 input volts. U.L. Listed, CSA approved. Minimize or Learn More more... |
Magnetic Ballast, F30T12/RS or F40T12/RS, F34T12
Advance Transformer # RL140TPI
Low power factor. For one lamp type F30T12/RS or F40T12/RS, F34T12. 3' or 4' lamp length. 30 or 40 lamp watts, 120 input volts. U.L. Listed. Minimize or Learn More more... |